COMPARATIVE STUDY
JOURNAL ARTICLE
Add like
Add dislike
Add to saved papers

Exercise performance in patients with end-stage heart failure after implantation of a left ventricular assist device and after heart transplantation: an outlook for permanent assisting?

OBJECTIVES: We sought to study exercise capacity at different points in time after left ventricular assist device (LVAD) implantation and subsequent heart transplantation (HTx).

BACKGROUND: The lack of donor organs warrants alternatives for transplantation.

METHODS: Repeat treadmill testing with respiratory gas analysis was performed in 15 men with a LVAD. Four groups of data are presented. In group A (n = 10), the exercise capacities at 8 weeks and 12 weeks after LVAD implantation were compared. In group B (n = 15), the data at 12 weeks are presented in more detail. In group C (n = 9), sequential analysis of exercise capacity was performed at 12 weeks after LVAD implantation and at 12 weeks and one year after HTx. In group D, exercise performance one year after HTx in patients with (n = 10) and without (n = 20) a previous assist device was compared.

RESULTS: In group A, peak oxygen consumption (Vo2) increased from 21.3+/-3.8 to 24.2+/-4.8 ml/kg body weight per min (p < 0.003), accompanied by a decrease in peak minute ventilation/ carbon dioxide production (VE/Vco2) (39.4+/-10.1 to 36.3+/-8.2; p < 0.03). In group B, peak Vo2 12 weeks after LVAD implantation was 23.0+/-4.4 ml/kg per min. In group C, levels of peak Vo2 12 weeks after LVAD implantation and 12 weeks and one year after HTx were comparable (22.8+/-5.3, 24.6+/-3.3 and 26.2+/-3.8 ml/kg per min, respectively; p = NS). In group D, there appeared to be no difference in percent predicted peak Vo2 in patients with or without a previous LVAD (68+/-13% vs. 74+/-15%; p < 0.37), although, because of the small numbers, the power of this comparison is limited (0.45 to detect a difference of 10%).

CONCLUSIONS: Exercise capacity in patients with a LVAD increases over time; 12 weeks after LVAD implantation, Vo2 is comparable to that at 12 weeks and one year after HTx. Previous LVAD implantation does not seem to adversely affect exercise capacity after HTx.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app