Add like
Add dislike
Add to saved papers

Transcatheter closure of secundum atrial septal defects, a ventricular septal defect, and a patent arterial duct.

We report our clinical experience with the newly developed Amplatzer device in transcatheter closure of nine atrial septal defects (ASDs), one ventricular septal defect (VSD), and one patent arterial duct (PDA). Eleven patients with ASD (age range 2.5-18 years) selected according to the location and size of the defect by transesophageal echocardiography (TEE), a five-year-old patient with muscular VSD and a one-year-old patient with PDA were considered for transcatheter closure with Amplatzer devices. All procedures were performed under general anesthesia with fluoroscopic and TEE guidance, following a routine hemodynamic evaluation in the catheter laboratory. The optimal device size was selected after the balloon sizing of the ASDs. The sizes of the VSD and PDA were measured on TEE and angiography. The patients were discharged at 24 hours, after an evaluation with x-ray, electrocardiogram (ECG), and echocardiography; they were on 3-5 mg/kg/day aspirin and infective endocarditis prophylaxis for six months after the procedure. They were reassessed at six to eight weeks and Holter monitoring was done in addition. Devices were used for nine ASD patients, and for the VSD and the PDA patients. Mean ASD size was 14.3 +/- 5.3 mm at TEE and 18.3 +/- 4.3 mm at balloon sizing (p=0.02). The mean size of the device was 18.7 +/- 4.2 mm. The procedure time and the fluoroscopy time were 46.1 +/- 12.3 and 12.9 +/- 1.6 minutes, respectively. Immediately after the procedure, four patients (44%) had trivial shunts (TS). TS remained in only two during discharge, and no shunt was observed at second evaluation. The devices were similarly applied to VSD (12-7 mm) and PDA (8-6 mm) patients. Both cases had TS immediately, which disappeared at 24 hours. None of the patients had major complications. Junctional rhythm developed in one patient, and another patient had frequent supraventricular extrasystoles. Amplatzer is an effective and safe device for transcatheter closure of ASD, VSD, or PDA, especially in pediatric patients.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app