Clinical Trial
Clinical Trial, Phase III
Comparative Study
Evaluation Studies
Journal Article
Multicenter Study
Add like
Add dislike
Add to saved papers

Off-site evaluation of liver lesion detection by Gd-BOPTA-enhanced MR imaging.

The aim of this study was to determine the efficacy of Gd-BOPTA-enhanced MRI in liver lesion detection in comparison with unenhanced MRI and dynamic CT. The image sets of 148 of 151 patients enrolled in a multicenter German phase-III trial were evaluated by two independent radiologists unaffiliated with the investigating centers. Patients underwent a routine MRI protocol comprising T2- and T1-weighted spin-echo and T1-weighted gradient-echo (GE) sequences pre and 1 h post 0.1 mmol/kg Gd-BOPTA (Bracco-Byk Gulden, Konstanz, Germany). Additionally, a serial T1-weighted GE scan was performed after administration of the first half of the dose. All patients underwent dynamic contrast-enhanced CT. The evaluation was performed with regard to the number and size of lesions detected per patient by each modality or sequence. Furthermore, all pre CM and pre + post CM image sets were analyzed for number of lesions per patient. Both readers detected significantly more lesions in the contrast-enhanced image set compared with the unenhanced image set (32 and 39 %, respectively; p < 0.0001). While contrast-enhanced CT detected a similar number of lesions to unenhanced MRI, it was clearly inferior to contrast-enhanced MRI (reader 1: p = 0.0117; reader 2: p = 0.0225). Of the T1-weighted scans performed, the dynamic and late T1-weighted GE exams contributed most to the increased lesion detection rate (reader 1: p = 0.0007; reader 2: p = 0.0037). The size of the smallest lesion detected by means of MRI was significantly larger in the pre-CM image sets than in the pre + post CM image sets (reader 1: p = 0.001; reader 2: p < 0.0001). Gd-BOPTA-enhanced MRI detected significantly smaller lesions than contrast-enhanced CT (reader 1: p = 0.0117; reader 2: p = 0.0925). Gd-BOPTA-enhanced MR imaging improves liver lesion detection significantly over unenhanced MRI and dynamic CT.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app