We have located links that may give you full text access.
COMPARATIVE STUDY
JOURNAL ARTICLE
RESEARCH SUPPORT, NON-U.S. GOV'T
Carpal tunnel syndrome: assessment by turbo spin echo, spin echo, and magnetization transfer imaging applied in a low-field MR system.
Journal of Computer Assisted Tomography 2001 January
PURPOSE: The purpose of this work was to evaluate patients with carpal tunnel syndrome (CTS) using a low-field extremity MR system (E-MRI: 0.2 T).
METHOD: Twenty-two patients with typical findings of CTS and 30 control persons were imaged on an E-MRI. Axial T2-weighted turbo SE (TSE), T1-weighted SE sequences, and 2D GRE magnetization transfer (MTC) sequences were compared. SE and MTC sequences were obtained before and after contrast agent administration (0.1 mmol/kg body wt of Gd-DTPA). Two readers evaluated typical MR findings of CTS independently.
RESULTS: Patients with CTS demonstrated palmar bowing of the flexor retinaculum significantly more often. The normal or edematous median nerve was best identified on TSE and MTC scans (kappa = 0.59 and 0.8). The MTC sequences showed perineural enhancement significantly better than respective T1-weighted SE sequences but were rated second in comparison with T2-weighted TSE scans.
CONCLUSION: At low-field strength, median nerve edema is best depicted on T2-weighted TSE sequences, whereas MTC sequences are most sensitive to perineural contrast enhancement.
METHOD: Twenty-two patients with typical findings of CTS and 30 control persons were imaged on an E-MRI. Axial T2-weighted turbo SE (TSE), T1-weighted SE sequences, and 2D GRE magnetization transfer (MTC) sequences were compared. SE and MTC sequences were obtained before and after contrast agent administration (0.1 mmol/kg body wt of Gd-DTPA). Two readers evaluated typical MR findings of CTS independently.
RESULTS: Patients with CTS demonstrated palmar bowing of the flexor retinaculum significantly more often. The normal or edematous median nerve was best identified on TSE and MTC scans (kappa = 0.59 and 0.8). The MTC sequences showed perineural enhancement significantly better than respective T1-weighted SE sequences but were rated second in comparison with T2-weighted TSE scans.
CONCLUSION: At low-field strength, median nerve edema is best depicted on T2-weighted TSE sequences, whereas MTC sequences are most sensitive to perineural contrast enhancement.
Full text links
Trending Papers
Monitoring Macro- and Microcirculation in the Critically Ill: A Narrative Review.Avicenna Journal of Medicine 2023 July
Euglycemic Ketoacidosis in Two Patients Without Diabetes After Introduction of Sodium-Glucose Cotransporter 2 Inhibitor for Heart Failure With Reduced Ejection Fraction.Diabetes Care 2023 November 22
ASA Consensus-based Guidance on Preoperative Management of Patients on Glucagon-like Peptide-1 Receptor Agonists.Anesthesiology 2023 November 21
Tranexamic Acid for Traumatic Injury in the Emergency Setting: A Systematic Review and Bias-Adjusted Meta-Analysis of Randomized Controlled Trials.Annals of Emergency Medicine 2023 November 22
Association between postinduction hypotension and postoperative mortality: a single-centre retrospective cohort study.Canadian Journal of Anaesthesia 2023 November 22
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
Read by QxMD is copyright © 2021 QxMD Software Inc. All rights reserved. By using this service, you agree to our terms of use and privacy policy.
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app