Lung collapse during low tidal volume ventilation in acute respiratory distress syndrome.
Respiratory Care 2001 January
BACKGROUND: Current ventilator management for acute respiratory distress syndrome (ARDS) incorporates low tidal volume (V(T)) ventilation in order to limit ventilator-induced lung injury. Low V(T) ventilation in supine patients, without the use of intermittent hyperinflations, may cause small airway closure, progressive atelectasis, and secretion retention. Use of high positive end-expiratory pressure (PEEP) levels with low V(T) ventilation may not counter this effect, because regional differences in intra-abdominal hydrostatic pressure may diminish the volume-stabilizing effects of PEEP.
CASE SUMMARY: A 35-year-old man with abdominal compartment syndrome (intra-abdominal pressure > 48 cm H2O developed ARDS and was treated with V(T) of 4.5 mL/kg and PEEP of 20 cm H2O. Despite aggressive fluid therapy, appropriate airway humidification and tracheal suctioning, the patient developed complete bronchial obstruction, involving the entire right lung and left upper lobe. After bronchoscopy the patient was placed on a higher V(T) (7.0 mL/kg). Intermittent PEEP was instituted at 30 cm H2O for 2 breaths every 3 minutes. This intermittently raised the end-inspiratory plateau pressure from 38 cm H2O to 50 cm H2O. With the same airway humidity and tracheal suctioning practices bronchial obstruction did not reoccur.
CONCLUSION: Low V(T) ventilation in ARDS may increase the risk of small airway closure and retained secretions. This adverse effect highlights the importance of pulmonary hygiene measures in ARDS during lung-protective ventilation.
CASE SUMMARY: A 35-year-old man with abdominal compartment syndrome (intra-abdominal pressure > 48 cm H2O developed ARDS and was treated with V(T) of 4.5 mL/kg and PEEP of 20 cm H2O. Despite aggressive fluid therapy, appropriate airway humidification and tracheal suctioning, the patient developed complete bronchial obstruction, involving the entire right lung and left upper lobe. After bronchoscopy the patient was placed on a higher V(T) (7.0 mL/kg). Intermittent PEEP was instituted at 30 cm H2O for 2 breaths every 3 minutes. This intermittently raised the end-inspiratory plateau pressure from 38 cm H2O to 50 cm H2O. With the same airway humidity and tracheal suctioning practices bronchial obstruction did not reoccur.
CONCLUSION: Low V(T) ventilation in ARDS may increase the risk of small airway closure and retained secretions. This adverse effect highlights the importance of pulmonary hygiene measures in ARDS during lung-protective ventilation.
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app