Evaluation of transesophageal echocardiography for diagnosis of traumatic aortic injury.
Anesthesiology 2000 December
BACKGROUND: Traumatic aortic injury is a frequent cause of death after blunt trauma, but few patients survive to reach a trauma center. The role of transesophageal echocardiography (TEE) in the diagnosis of traumatic aortic injury remains debated.
METHODS: Over a 9-yr period, 209 blunt trauma patients (mean age, 34 +/- 13 yr) were suspected of having traumatic aortic injury because of enlarged mediastinum and/or sudden deceleration, and underwent TEE and angiography (aortography and/or contrast-enhanced computed tomography.
RESULTS: Traumatic aortic injury was diagnosed in 42 patients (20%). Angiography (aortography and/or contrast-enhanced computed tomography) was less accurate (sensitivity, 83%; specificity, 100%) than TEE (sensitivity, 98%; specificity, 100%) for the diagnosis of aortic injury because it failed to diagnose most minor injuries (intramural hematoma or limited intimal flap, n = 7). However, when considering only patients with major aortic injury (n = 33; i.e., those who might need surgery), angiography (sensitivity, 97%; specificity, 100%) and TEE (sensitivity, 97%; specificity, 100%) were equivalent.
CONCLUSION: Transesophageal echocardiography is an accurate method for diagnosis of traumatic aortic injury. Nevertheless, the clinical implications of limited aortic injuries diagnosed by the technique have yet to be determined.
METHODS: Over a 9-yr period, 209 blunt trauma patients (mean age, 34 +/- 13 yr) were suspected of having traumatic aortic injury because of enlarged mediastinum and/or sudden deceleration, and underwent TEE and angiography (aortography and/or contrast-enhanced computed tomography.
RESULTS: Traumatic aortic injury was diagnosed in 42 patients (20%). Angiography (aortography and/or contrast-enhanced computed tomography) was less accurate (sensitivity, 83%; specificity, 100%) than TEE (sensitivity, 98%; specificity, 100%) for the diagnosis of aortic injury because it failed to diagnose most minor injuries (intramural hematoma or limited intimal flap, n = 7). However, when considering only patients with major aortic injury (n = 33; i.e., those who might need surgery), angiography (sensitivity, 97%; specificity, 100%) and TEE (sensitivity, 97%; specificity, 100%) were equivalent.
CONCLUSION: Transesophageal echocardiography is an accurate method for diagnosis of traumatic aortic injury. Nevertheless, the clinical implications of limited aortic injuries diagnosed by the technique have yet to be determined.
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app