JOURNAL ARTICLE
RESEARCH SUPPORT, NON-U.S. GOV'T
Add like
Add dislike
Add to saved papers

Range of motion and lordosis of the lumbar spine: reliability of measurement and normative values.

Spine 2001 January 2
STUDY DESIGN: Repeated measures for intratester reliability were performed.

OBJECTIVES: To investigate the intratester reliability of a new measurement technique that evaluates lumbar range of motion in three planes using a pelvic restraint device, and to examine the reliability of lumbar lordosis measurement by inclinometer technique. Preliminary normative data on lumbar range of motion and lumbar lordosis were collected for comparison with the findings of previous studies.

SUMMARY OF BACKGROUND DATA: Various noninvasive measurement methods have been developed for recording lumbar range of motion. However, pelvic movement was not effectively restricted during the use of these measurement techniques. The use of the pelvic restraint device to measure lumbar range of motion has not been investigated previously. Very few studies have investigated the reliability of quantifying lumbar lordosis by the inclinometer technique.

METHODS: Normative values were measured in 35 healthy men, and 12 of these subjects were included for the reliability study. Pelvic motion was limited by the pelvic restraint device during lumbar range of motion measurement in standing. An inclinometer was used for evaluation of lumbar flexion, extension, lateral flexion, and lumbar lordosis, whereas a lumbar rotameter was used to measure axial rotation.

RESULTS: Good intratester reliability was shown in the lumbar range of motion and lordosis measurement. Most of the intraclass correlation coefficient and Pearson's r values (accompanied with nonsignificant paired t tests) were greater than 0.9, and most of the intrasubject coefficients of variation were less than 10%. The values of lumbar range of motion in three planes and lumbar lordosis found in the current study were comparable with those from most of the previous studies on these measurements in the normal population.

CONCLUSIONS: Inclinometer and lumbar rotameter measurements with the use of a pelvic restraint device are reliable for measuring lumbar spine range of motion. Use of the inclinometer technique to record lumbar lordosis also is a reliable measure.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app