We have located links that may give you full text access.
Sources of error when tracking irrigation fluids during hysteroscopic procedures.
STUDY OBJECTIVE: To evaluate the ability of circulating nurses to estimate input and outgo of irrigating fluids used during hysteroscopic procedures in a hospital operating room.
DESIGN: Simulation of intraoperative measurements (Canadian Task Force classification II-1).
SETTING: Operating room. Intervention. Circulating nurses estimated fluid volumes under circumstances simulating actual conditions of hysteroscopic ablative or resection procedures.
MEASUREMENTS AND MAIN RESULTS: Three-liter glycine irrigation bags were overfilled by an average of 2.8% (62-125 ml). Estimates of fluid remaining in partially emptied bags were in error by an average ranging from 4% to 50%/bag (largest error 10-55%, 157-401 ml). Estimates of fluid in kick buckets were in error by an average of 10% to 39% (largest error 22-66%, 232-903 ml). Visual estimates of fluid on the operating room floor were in error by an average of 56% to 67% (largest error 65-81%, 182-840 ml). Estimates of fluid in suction canisters were consistent among nurses. The accuracy of measurements for partially filled suction canisters primarily depended on the accuracy of canister calibration. Volume contained in cascaded suction canisters from an actual surgical procedure was grossly different from rated capacity.
CONCLUSION: Accurate tracking of irrigation fluid during hysteroscopic procedures is difficult. Even with a mechanical measuring system, fluid lost on the floor can introduce sizable errors. Estimation errors can easily and quickly accumulate to clinically significant volumes. Use of an automated mechanical fluid-tracking system with devices to capture fluid lost from the surgical field is recommended.
DESIGN: Simulation of intraoperative measurements (Canadian Task Force classification II-1).
SETTING: Operating room. Intervention. Circulating nurses estimated fluid volumes under circumstances simulating actual conditions of hysteroscopic ablative or resection procedures.
MEASUREMENTS AND MAIN RESULTS: Three-liter glycine irrigation bags were overfilled by an average of 2.8% (62-125 ml). Estimates of fluid remaining in partially emptied bags were in error by an average ranging from 4% to 50%/bag (largest error 10-55%, 157-401 ml). Estimates of fluid in kick buckets were in error by an average of 10% to 39% (largest error 22-66%, 232-903 ml). Visual estimates of fluid on the operating room floor were in error by an average of 56% to 67% (largest error 65-81%, 182-840 ml). Estimates of fluid in suction canisters were consistent among nurses. The accuracy of measurements for partially filled suction canisters primarily depended on the accuracy of canister calibration. Volume contained in cascaded suction canisters from an actual surgical procedure was grossly different from rated capacity.
CONCLUSION: Accurate tracking of irrigation fluid during hysteroscopic procedures is difficult. Even with a mechanical measuring system, fluid lost on the floor can introduce sizable errors. Estimation errors can easily and quickly accumulate to clinically significant volumes. Use of an automated mechanical fluid-tracking system with devices to capture fluid lost from the surgical field is recommended.
Full text links
Trending Papers
A Personalized Approach to the Management of Congestion in Acute Heart Failure.Heart International 2023
Potential Mechanisms of the Protective Effects of the Cardiometabolic Drugs Type-2 Sodium-Glucose Transporter Inhibitors and Glucagon-like Peptide-1 Receptor Agonists in Heart Failure.International Journal of Molecular Sciences 2024 Februrary 21
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app