Radiation exposure to the spine surgeon during fluoroscopically assisted pedicle screw insertion.
Spine 2000 October 16
STUDY DESIGN: In vitro study to determine occupational radiation exposure during lumbar fluoroscopy.
OBJECTIVES: To assess radiation exposure to the spine surgeon during fluoroscopically assisted thoracolumbar pedicle screw placement.
SUMMARY OF BACKGROUND DATA: Occupational radiation exposure during a variety of fluoroscopically assisted musculoskeletal procedures has been previously evaluated. No prior study has assessed fluoroscopy-related radiation exposure to the spine surgeon.
METHODS: Bilateral pedicle screw placement (T11-S1) was performed in six cadavers using lateral fluoroscopic imaging. Radiation dose rates to the surgeon's neck, torso, and dominant hand were measured with dosimeter badges and thermolucent dosimeter (TLD) rings. Radiation levels were also quantified at various distances from the dorsal lumbar surface using an ion chamber radiation survey meter.
RESULTS: The mean dose rate to the neck was 8.3 mrem/min. The dose rate to the torso was greatest when the surgeon was positioned ipsilateral to the beam source (53.3 mrem/min, compared with 2.2 mrem/min on the contralateral side). The average hand dose rate was 58.2 mrem/min. A significant increase in hand dose rate was associated with placement of screws ipsilateral to the beam source (P = 0.0005) and larger specimens (P = 0.0007). Radiation levels significantly decreased as distance from the beam source and dorsal body surface increased. The greatest levels of radiation were noted on the side where the primary radiograph beam entered the cadaver.
CONCLUSION: Fluoroscopically assisted thoracolumbar pedicle screw placement exposes the spine surgeon to significantly greater radiation levels than other, nonspinal musculoskeletal procedures that involve the use of a fluoroscope. In fact, dose rates are up to 10-12 times greater. Spine surgeons performing fluoroscopically assisted thoracolumbar procedures should monitor their annual radiation exposure. Measures to reduce radiation exposure and surgeon awareness of high-exposure body and hand positions are certainly called for.
OBJECTIVES: To assess radiation exposure to the spine surgeon during fluoroscopically assisted thoracolumbar pedicle screw placement.
SUMMARY OF BACKGROUND DATA: Occupational radiation exposure during a variety of fluoroscopically assisted musculoskeletal procedures has been previously evaluated. No prior study has assessed fluoroscopy-related radiation exposure to the spine surgeon.
METHODS: Bilateral pedicle screw placement (T11-S1) was performed in six cadavers using lateral fluoroscopic imaging. Radiation dose rates to the surgeon's neck, torso, and dominant hand were measured with dosimeter badges and thermolucent dosimeter (TLD) rings. Radiation levels were also quantified at various distances from the dorsal lumbar surface using an ion chamber radiation survey meter.
RESULTS: The mean dose rate to the neck was 8.3 mrem/min. The dose rate to the torso was greatest when the surgeon was positioned ipsilateral to the beam source (53.3 mrem/min, compared with 2.2 mrem/min on the contralateral side). The average hand dose rate was 58.2 mrem/min. A significant increase in hand dose rate was associated with placement of screws ipsilateral to the beam source (P = 0.0005) and larger specimens (P = 0.0007). Radiation levels significantly decreased as distance from the beam source and dorsal body surface increased. The greatest levels of radiation were noted on the side where the primary radiograph beam entered the cadaver.
CONCLUSION: Fluoroscopically assisted thoracolumbar pedicle screw placement exposes the spine surgeon to significantly greater radiation levels than other, nonspinal musculoskeletal procedures that involve the use of a fluoroscope. In fact, dose rates are up to 10-12 times greater. Spine surgeons performing fluoroscopically assisted thoracolumbar procedures should monitor their annual radiation exposure. Measures to reduce radiation exposure and surgeon awareness of high-exposure body and hand positions are certainly called for.
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app