CLINICAL TRIAL
CONTROLLED CLINICAL TRIAL
JOURNAL ARTICLE
Add like
Add dislike
Add to saved papers

Cardiorespiratory and thermoregulatory response of working in fire-fighter protective clothing in a temperate environment.

Ergonomics 2000 September
The cardiorespiratory and thermal responses of two intensities of treadmill exercise were compared for brief periods (12 min) in fire ensemble (FE) but without self contained breathing apparatus, and sports ensemble (SE), in a temperature environment. A further experiment explored the responses of subjects exercising in FE over a prolonged period (60 min). Eighteen male fire-fighters wearing either FE or SE walked on a level treadmill for 6 min at 5 km x h(-1) increasing to 7 km x h(-1) for 6 min. Following a recovery interval of 1 h, the exercise protocol was repeated in the second ensemble; the order of ensemble was balanced. Heart rate (HR), rectal temperature (Tre), VO2 max and rating of perceived exertion (RPE) were monitored continuously under both ensembles. At 7 km x h(-1), VO2 was significantly higher (p<0.05) in FE (36.1 and 39.9 ml x kg(-1) x min(-1)) than in SE and represented 74% VO2 max. There were no changes Tre. In experiment 2, following a rest interval of at least 36 h, eight subjects in FE walked on the treadmill at 6 km x h (gradient 10%) for 60 min also in temperate conditions, where HR, Tre and RPE were recorded at 10-min intervals. During the 60-min exercise in FE, HR reached 161 beats x min(-1) and Tre increased to 38.3 degrees C. Despite considerable subject discomfort, Tre remained below dangerous levels (38.4 degrees C). When RPE were compared with a physiological strain index (PSI) calculated from Tre and HR data over 60 min, there was no significant difference (p<0.05) with a correlation coefficient (r) of 0.98. The results suggest that RPE and PSI are closely related when exercise is sufficiently prolonged or intense to elevate Tre and HR in fire-fighters wearing FE in temperate conditions. If further investigation confirms this relationship for hot humid conditions in which fire-fighters operate, then with training, it may provide individuals with a valid measure of dangerous levels of perceived heat strain.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

Managing Alcohol Withdrawal Syndrome.Annals of Emergency Medicine 2024 March 26

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app