Hemodynamically optimized temporary cardiac pacing after surgery for congenital heart defects.

Disturbance of normal AV synchrony and dyssynchronous ventricular contraction may be deleterious in patients with otherwise compromised hemodynamics. This study evaluated the effect of hemodynamically optimized temporary dual chamber pacing in patients after surgery for congenital heart disease. Pacing was performed in 23 children aged 5 days to 7.7 years (median 7.3 months) with various postoperative dysrhythmias, low cardiac output, and/or high inotropic support and optimized to achieve the highest systolic and mean arterial pressures. The following four pacing modes were used: (1) AV synchronous or AV sequential pacing with individually optimized AV delay in 11 patients with first- to third-degree AV block; (2) AV sequential pacing using transesophageal atrial pacing in combination with a temporary DDD pacemaker for atrial tracking and ventricular pacing in three patients with third-degree AV block and junctional ectopic tachycardia, respectively, who had poor signal and exit block on atrial epicardial pacing wires; (3) R wave synchronized atrial pacing in eight patients with junctional ectopic tachycardia and impaired antegrade AV conduction precluding the use of atrial overdrive pacing; (4) Atrio-biventricular sequential pacing in two patients. Pressures measured during optimized pacing were compared to baseline values at underlying rhythm (13 patients with first-degree AV block or junctional ectopic tachycardia) or during pacing modes commonly used in the given clinical situation: AAI pacing (1 patient with slow junctional rhythm and first-degree AV block during atrial pacing), VVI pacing (2 patients with third-degree AV block and exit block and poor sensing on epicardial atrial pacing wires) and dual-chamber pacing with AV delays set to 100 ms (atrial tracking) or 150 ms (AV sequential pacing) in 7 patients with second- to third-degree AV block and functional atrial pacing wires. Optimized pacing led to a significant increase in arterial systolic (mean) pressure from 71.5 +/- 12.5 (52.3 +/- 9.0) to 80.5 +/- 12.2 (59.7 +/- 9.1) mmHg (P < 0.001 for both) and a decrease in central venous (left atrial) pressure from 12.3 +/- 3.4 (10.5 +/- 3.2) to 11.0 +/- 3.0 (9.2 +/- 2.7) mmHg (P < 0.001 and < 0.005, respectively). In conclusion, several techniques of individually optimized temporary dual chamber pacing leading to optimal AV synchrony and/or synchronous ventricular contraction were successfully used to improve hemodynamics in patients with heart failure and selected dysrhythmias after congenital heart surgery.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app