How many lymph nodes are enough during sentinel lymphadenectomy for primary melanoma?

Surgery 2000 August
BACKGROUND: Sentinel lymph node (SLN) biopsy has been shown to reliably identify nodal metastases and the subsequent need for further surgical and adjuvant therapy in patients with cutaneous melanoma. Although SLN identification rates have improved with the addition of radioactive colloid to the blue dye technique, it remains unclear how many lymph nodes should be removed to accurately determine the histologic status of the nodal basin. The objective of this study was to determine the optimal extent of SLN biopsy in these patients.

METHODS: The records of 633 consecutive patients with melanoma (765 nodal basins) whose primary treatment included SLN biopsy with the use of a combination of blue dye and technetium Tc 99 labeled sulfur colloid were reviewed. SLN biopsy consisted of the removal of all of the blue-stained nodes and all nodes with radiotracer uptake activity of at least twice background.

RESULTS: SLN biopsy was successful in 765 of 772 basins (99%). A mean of 1.9 SLNs (median, 2 SLNs) per basin were excised. At least 3 SLNs were removed in 176 basins (23%). The overall histologic status of a basin was always established by the first or second SLN harvested (ie, in no patient was the third or subsequent SLN positive when 1 of the first 2 was not). Of the 124 basins containing lymphatic metastases, the SLN that contained the maximal radiotracer uptake (hottest) and/or stained blue was pathologically positive in 118 basins (95%). In only 6 of the 124 positive basins (5%) was the sole evidence of occult nodal metastases identified in an SLN that was neither blue-stained nor the hottest. All but 1 of these SLNs had counts that were at least 66% of the hottest node in the basin.

CONCLUSIONS: With a combined modality approach to SLN biopsy, removal of more than 2 SLNs did not provide information that upstaged any patient with primary melanoma. Removal of additional nonblue SLN(s) that contained radioactive counts of at least twice background but lower than two thirds of the SLNs with maximal radiotracer uptake affected patient management in less than 0.2% of all cases. These findings may be helpful in minimizing the extent of surgery and perhaps in reducing the costs and resource use associated with operating room time and pathologic examination.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app