We have located links that may give you full text access.
Comparative Study
Journal Article
Usefulness of three-dimensional echocardiography for the evaluation of mitral valve prolapse: an intraoperative study.
Journal of Heart Valve Disease 2000 May
BACKGROUND AND AIM OF THE STUDY: The study aim was to evaluate the feasibility of intraoperative three-dimensional (3D) transesophageal echocardiography (TEE) in patients referred for mitral valve prolapse (MVP) repair and to compare two-dimensional (2D) TEE and 3D TEE and surgical findings.
METHODS: Forty-six patients (mean age 67 +/- 11 years) underwent 3D TEE intraoperatively. Measurements were made of the posterior part of mitral annulus circumference (PMAC), and the width of mitral valve surgical resection on the mitral annulus (WMVR). Using 3D TEE, MVP topography was described, and PMAC in diastole and the width of implantation of MVP on the mitral annulus (WMVP) in systole were measured.
RESULTS: 3D TEE was successful in 42 patients (91%). 2D and 3DTEE correctly predicted MVP localization in 38 (90%) and 36 (86%) patients, respectively (p = NS). 3D TEE and surgical PMAC were 89 +/- 13 and 93 +/- 21 mm, respectively (p = 0.01, R = 0.42). WMVR and WMVP were 28 +/- 11 mm and 26 +/- 11 mm, respectively (p <0.0001, R = 0.82). WMVR/anatomic PMAC (0.29 +/- 0.11) and WMVP/3D echo PMAC (0.32 +/- 0.11) were correlated (p <0.0001, R= 0.69).
CONCLUSION: Intraoperative 3D TEE evaluation of MVP is feasible. MVP width and its ratio to the mitral annulus were assessed, and found to correlate with surgical findings. These 3D data may be of value to the surgeon when performing mitral valve repair.
METHODS: Forty-six patients (mean age 67 +/- 11 years) underwent 3D TEE intraoperatively. Measurements were made of the posterior part of mitral annulus circumference (PMAC), and the width of mitral valve surgical resection on the mitral annulus (WMVR). Using 3D TEE, MVP topography was described, and PMAC in diastole and the width of implantation of MVP on the mitral annulus (WMVP) in systole were measured.
RESULTS: 3D TEE was successful in 42 patients (91%). 2D and 3DTEE correctly predicted MVP localization in 38 (90%) and 36 (86%) patients, respectively (p = NS). 3D TEE and surgical PMAC were 89 +/- 13 and 93 +/- 21 mm, respectively (p = 0.01, R = 0.42). WMVR and WMVP were 28 +/- 11 mm and 26 +/- 11 mm, respectively (p <0.0001, R = 0.82). WMVR/anatomic PMAC (0.29 +/- 0.11) and WMVP/3D echo PMAC (0.32 +/- 0.11) were correlated (p <0.0001, R= 0.69).
CONCLUSION: Intraoperative 3D TEE evaluation of MVP is feasible. MVP width and its ratio to the mitral annulus were assessed, and found to correlate with surgical findings. These 3D data may be of value to the surgeon when performing mitral valve repair.
Full text links
Related Resources
Trending Papers
Challenges in Septic Shock: From New Hemodynamics to Blood Purification Therapies.Journal of Personalized Medicine 2024 Februrary 4
Molecular Targets of Novel Therapeutics for Diabetic Kidney Disease: A New Era of Nephroprotection.International Journal of Molecular Sciences 2024 April 4
Perioperative echocardiographic strain analysis: what anesthesiologists should know.Canadian Journal of Anaesthesia 2024 April 11
The 'Ten Commandments' for the 2023 European Society of Cardiology guidelines for the management of endocarditis.European Heart Journal 2024 April 18
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app