[First experiences with a noninvasive patient set-up system for radiotherapy of the prostate].
PURPOSE: Highly conformal radiotherapy techniques require precise patient positioning. We report our first experience with a new cast system for fixation of the pelvis during stereotactically guided intensity modulated radiotherapy (IMRT) of the prostate with respect to positioning accuracy of the prostate.
MATERIAL AND METHODS: The immobilization device consists of a custom-made wrap-around body cast that extends from the abdomen to the thighs and a separate head mask, both made from Scotchcast, and attaches to a frame for extracranial stereotaxy. Sixteen CT-studies (> or = 25 slices, thickness: 3 mm) of 2 patients who were immobilized for IMRT of prostate tumors were evaluated with respect to set-up accuracy of bony structures and the prostate itself. CT-studies were performed immediately before or after a treatment fraction. Deviations of bony landmarks and anatomical landmarks inside the planning target volume were measured in all 3 dimensions.
RESULTS: Mean patient movements of 0.15 +/- 0.3 mm (latero-lateral), 0.9 +/- 1 mm (anterior-posterior), 1 +/- 1 mm (tranversal vectorial error) and < 3 mm slice thickness (craniocaudal) were recorded using bony landmarks and 0.9 +/- 0.9 mm (latero-lateral), 1.8 +/- 1.5 mm (anterior-posterior), 2.2 +/- 1.5 mm (transversal vectorial error) and < 3 mm (craniocaudal) using the confines of, or landmarks within the prostate. Standard deviations of absolute positioning error as an often used metric for positioning accuracy ranged between 0.3 and 1.7 mm in the transversal plane. The worst case transversal vectorial deviation for the prostate was 4.4 mm. Figure 4 summarizes the set-up accuracy of bony landmarks and the prostate.
CONCLUSION: The presented combination of a body cast and head mask system in a rigid stereotactic body frame ensures reliable noninvasive patient fixation for fractionated extracranial stereotactic radiotherapy. It provides precise and reliable positioning of the prostate and meets the requirements for highly conformal radiotherapy such as IMRT. No further improvement of repositioning can be achieved with external immobilization devices since the positioning error of the target relative to the skeleton exceeds the accuracy of the positioning of the skeleton itself.
MATERIAL AND METHODS: The immobilization device consists of a custom-made wrap-around body cast that extends from the abdomen to the thighs and a separate head mask, both made from Scotchcast, and attaches to a frame for extracranial stereotaxy. Sixteen CT-studies (> or = 25 slices, thickness: 3 mm) of 2 patients who were immobilized for IMRT of prostate tumors were evaluated with respect to set-up accuracy of bony structures and the prostate itself. CT-studies were performed immediately before or after a treatment fraction. Deviations of bony landmarks and anatomical landmarks inside the planning target volume were measured in all 3 dimensions.
RESULTS: Mean patient movements of 0.15 +/- 0.3 mm (latero-lateral), 0.9 +/- 1 mm (anterior-posterior), 1 +/- 1 mm (tranversal vectorial error) and < 3 mm slice thickness (craniocaudal) were recorded using bony landmarks and 0.9 +/- 0.9 mm (latero-lateral), 1.8 +/- 1.5 mm (anterior-posterior), 2.2 +/- 1.5 mm (transversal vectorial error) and < 3 mm (craniocaudal) using the confines of, or landmarks within the prostate. Standard deviations of absolute positioning error as an often used metric for positioning accuracy ranged between 0.3 and 1.7 mm in the transversal plane. The worst case transversal vectorial deviation for the prostate was 4.4 mm. Figure 4 summarizes the set-up accuracy of bony landmarks and the prostate.
CONCLUSION: The presented combination of a body cast and head mask system in a rigid stereotactic body frame ensures reliable noninvasive patient fixation for fractionated extracranial stereotactic radiotherapy. It provides precise and reliable positioning of the prostate and meets the requirements for highly conformal radiotherapy such as IMRT. No further improvement of repositioning can be achieved with external immobilization devices since the positioning error of the target relative to the skeleton exceeds the accuracy of the positioning of the skeleton itself.
Full text links
Related Resources
Trending Papers
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Anti-Arrhythmic Effects of Heart Failure Guideline-Directed Medical Therapy and Their Role in the Prevention of Sudden Cardiac Death: From Beta-Blockers to Sodium-Glucose Cotransporter 2 Inhibitors and Beyond.Journal of Clinical Medicine 2024 Februrary 27
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app