Striking findings concerning the variability in the measurement of the fetal renal collecting system.

OBJECTIVE: Using strict thresholds of normality, investigators have reported associations between fetal pyelectasis and aneuploidy, obstructive uropathy, postnatal pyeloplasty and vesicoureteral reflux. Although evidence continues to mount regarding the importance of fetal pyelectasis, little is known of the variability of collecting system measurements. To investigate the short-term variability and its relationship to bladder dilatation, the following study was conducted.

DESIGN: During May and June 1996, 20 mid- and late-trimester patients with varying degrees of fetal pyelectasis were recruited into this study. Each consented to undergo periodic (every 15 min for 2 h) ultrasound measurements of the fetal renal collecting systems and bladder. To account for anatomic and technical variability in measurement, we used both the sum of the transverse and anterior-posterior (AP) measurements of the collecting systems, and AP measurement alone for comparison. The variability of the collecting system measurements was assessed based upon gestational age, magnitude of pyelectasis and fetal bladder size.

RESULTS: We investigated 38 renal units in 20 patients (eight in the second trimester and 12 in the third). The mean(SE) AP diameter of all kidneys was 5.89(2.49) mm (range 15 (2-17) mm), and the sum of transverse and AP renal collecting system diameters was 13.91(5.73) mm (range 26 (4-31) mm). These data were normally distributed. When assessing the variability in individual kidneys over time, we found the mean variation (minimum to maximum) for the sum of the AP and transverse measurement to be 7.61(4.26) mm and for the AP measurement alone to be 3.80(2.49) mm. No relationship was found between variability of dilatation, magnitude of dilatation or fetal bladder size. Cyclic dilatation of the fetal bladder was observed in all cases. The mean time from maximal to minimal dilatation was 20 min (1.34 observations; range 12-30 min).

CONCLUSIONS: We found the size of the fetal renal collecting system to be highly variable over the course of a 2-h period. Seventy per cent of cases (14 of 20) had both normal (< 4 mm) and abnormal values (> or = 4 mm) during the 2-h study period. Significant caution should be used when considering the implications of renal collecting system dilatation based upon a single AP measurement.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

For the best experience, use the Read mobile app

Group 7SearchHeart failure treatmentPapersTopicsCollectionsEffects of Sodium-Glucose Cotransporter 2 Inhibitors for the Treatment of Patients With Heart Failure Importance: Only 1 class of glucose-lowering agents-sodium-glucose cotransporter 2 (SGLT2) inhibitors-has been reported to decrease the risk of cardiovascular events primarily by reducingSeptember 1, 2017: JAMA CardiologyAssociations of albuminuria in patients with chronic heart failure: findings in the ALiskiren Observation of heart Failure Treatment study.CONCLUSIONS: Increased UACR is common in patients with heart failure, including non-diabetics. Urinary albumin creatininineJul, 2011: European Journal of Heart FailureRandomized Controlled TrialEffects of Liraglutide on Clinical Stability Among Patients With Advanced Heart Failure and Reduced Ejection Fraction: A Randomized Clinical Trial.Review

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

Read by QxMD is copyright © 2021 QxMD Software Inc. All rights reserved. By using this service, you agree to our terms of use and privacy policy.

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app