Pumpless extracorporeal lung assist - experience with the first 20 cases.

OBJECTIVE: Long-term extracorporeal lung assist is limited by a significant mechanical blood trauma resulting in bleeding and hemolysis. To reduce the drawbacks of extracorporeal lung assist a new technique has been developed, by which the driving force for the extracorporeal circuit derives from the patients arterio-venous pressure gradient (pumpless extracorporeal lung assist). The aim of this clinical study was to test the feasibilty and effectiveness of pumpless extracorporeal lung assist in patients with acute respiratory distress syndrome.

METHODS: Twenty patients (41+/-16 years) with acute respiratory distress syndrome of various causes and failing respirator therapy were enrolled. The minimum hemodynamic requirements included a cardiac output (CO) >6 l/min and mean arterial pressure (MAP) >70 mmHg. Pumpless extracorporeal lung assist was established using a short circuit arterio-venous shunt including a special designed low-resistance membrane oxygenator which was placed between the patients legs.

RESULTS: At the time of inclusion FiO(2) in all patients was 1.0 (paO(2) 45.9+/-7 mmHg, paCO(2) 58.9+/-17 mmHg). After 24 h of pumpless extracorporeal lung assist FiO(2) was reduced to 0.8+/-0.1. A significant improvement in oxygenation (paO(2) 84.1+/-21 mmHg, P<0.05) and CO(2) removal (paCO(2) 32.7+/-5 mmHg, P<0.05) was notable. The mean extracorporeal flow was 2.6+/-0.6 l/min, which represented approximately 25% of the patients mean CO (10.8+/-2 l/min). The median assist time was 12+/-8 (1-32) days. Fifteen out of twenty patients were weaned off pumpless extracorporeal lung assist. Five out of twenty patients died while on the system (four sepsis, one ventricular fibrillation). Three out of twenty patients died after successful weaning on day 8, 30, and 50, respectively. Twelve out of twenty patients were discharged in a healthy state (overall survival 60%). Technical problems included thrombosis of the venous cannula (n=5), thrombus formation within the membrane oxygenator (n=2), membrane oxygenator plasma leakage (n=2), and membrane oxygenator contamination with Candida albicans. No bleeding complication was observed.

CONCLUSION: Pumpless extracorporeal lung assist is feasible and effective in a selected group of patients with acute respiratory distress syndrome but preserved hemodynamic function. By eliminating the pump and reducing the tubing length blood trauma can be minimized. Being very simple the system entails fewer risks of technical complications and also facilitates nursing care.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app