Add like
Add dislike
Add to saved papers

Patient positioning in prostate radiotherapy: is prone better than supine?

PURPOSE: To assess potential dose reductions to the rectum and to the bladder with three-dimensional conformal radiotherapy (3D-CRT) to the prostate in the prone as compared with the supine position; and to retrospectively evaluate treatment position reproducibility without immobilization devices.

METHODS AND MATERIALS: Eighteen patients with localized prostate cancer underwent pelvic CT scans and 3D treatment planning in prone and supine positions. Dose-volume histograms (DVHs) were constructed for the clinical target volume, the rectum and the bladder for every patient in both treatment positions. "Comparative DVHs" (cDVHs) were defined for the rectum and for the bladder: cDVH was obtained by subtracting the organ volume receiving a given dose increment in the prone position from the corresponding value in the supine position. These values were then integrated over the entire dose range. The prescribed dose to the planning target volume (PTV) was 74 Gy using a 6-field technique. To evaluate reproducibility, portal films were subsequently reviewed in 12 patients treated prone and 10 contemporary patients treated supine (controls). No immobilization devices were used. Deviations in the anterio-posterior (X) and cranio-caudal (Y) axes were measured. Mean treatment position variation, total setup variation, systematic setup variation, and random setup variation were obtained.

RESULTS: Prone position was associated with a higher dose to the rectum or to the bladder in 6 (33%) and 7 (39%) patients, respectively. A simultaneously higher dose to rectum and bladder was noted in 2 (11%) patients in prone and in 7 (39%) patients in supine. Rectal and bladder volumes were frequently larger in prone than in supine: mean prone/supine volume ratios were 1.21 (SD, 0.68) and 1.03 (SD, 1.32), respectively. In these cases cDVH analysis more often favored the prone position. Mean treatment position variation and total setup variation were similar for both prone and supine plans. A higher systematic setup variation was observed in prone positioning: 2.7 mm vs. 1.9 mm (X axis) and 4.1 mm vs. 2.2 mm (Y axis). The random variation was similar for both prone and supine: 4. 0 mm vs. 3.6 mm (X axis) and 3.7 mm vs. 3.6 mm (Y axis).

CONCLUSIONS: Prone position 3D-CRT is frequently, but not always, associated with an apparent dose reduction to the rectum and/or to the bladder for prostate cancer patients. As suggested by the increased mean prone/supine rectal volume ratio, the advantage of prone positioning for the rectum may be artifactual, at least partly reflecting a position-dependent rectal air volume, which may significantly vary from treatment to treatment. In the absence of immobilization devices, daily setup reproducibility appears less accurate for the prone position, primarily due to systematic setup variations.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app