The accuracy of physical examination to detect abdominal aortic aneurysm.
Archives of Internal Medicine 2000 March 28
BACKGROUND: Abdominal palpation during physical examination is an important means of detecting abdominal aortic aneurysm (AAA), but limited information is available on its accuracy.
METHODS: Two hundred subjects (aged 51-88 years), 99 with and 101 without AAA as determined by previous ultrasound, each underwent physical examination of the abdomen by 2 internists who were blinded to each other's findings and to the ultrasound diagnosis.
RESULTS: The overall accuracy of abdominal palpation for detecting AAA was as follows: sensitivity, 68% (95% confidence interval [CI], 60%-76%); specificity, 75% (95% CI, 68%-82%); positive likelihood ratio, 2.7 (95% CI, 2.0-3.6); negative likelihood ratio 0.43 (95% CI, 0.33-0.56). Interobserver pair agreement for AAA vs no AAA between the first and second examinations was 77% (kappa = 0.53). Sensitivity increased with AAA diameter, from 61% for AAAs of 3.0 to 3.9 cm, to 69% for AAAs of 4.0 to 4.9 cm, 72% for AAAs of 4.0 cm or larger, and 82% for AAAs of 5.0 cm or larger. Sensitivity in subjects with an abdominal girth less than 100 cm (40-in waistline) was 91% vs 53% for girth of 100 cm or greater (P<.001). When girth was 100 cm or greater and the aorta was palpable, sensitivity was 82%. When girth was less than 100 cm and the AAA was 5.0 cm or larger, sensitivity was 100% (12 examinations). Factors independently associated with correct examination findings included AAA diameter (odds ratio [OR], 1.95 per centimeter increase; 95% CI, 1.06-3.58); abdominal girth (OR, 0.90 per centimeter increase; 95% CI, 0.87-0.94); and the examiner's assessment that the abdomen was not tight (OR, 2.68; 95% CI, 1.17-6.13).
CONCLUSIONS: Abdominal palpation has only moderate overall sensitivity for detecting AAA, but appears to be highly sensitive for diagnosis of AAAs large enough to warrant elective intervention in patients who do not have a large girth. Abdominal palpation has good sensitivity even in patients with a large girth if the aorta is palpable.
METHODS: Two hundred subjects (aged 51-88 years), 99 with and 101 without AAA as determined by previous ultrasound, each underwent physical examination of the abdomen by 2 internists who were blinded to each other's findings and to the ultrasound diagnosis.
RESULTS: The overall accuracy of abdominal palpation for detecting AAA was as follows: sensitivity, 68% (95% confidence interval [CI], 60%-76%); specificity, 75% (95% CI, 68%-82%); positive likelihood ratio, 2.7 (95% CI, 2.0-3.6); negative likelihood ratio 0.43 (95% CI, 0.33-0.56). Interobserver pair agreement for AAA vs no AAA between the first and second examinations was 77% (kappa = 0.53). Sensitivity increased with AAA diameter, from 61% for AAAs of 3.0 to 3.9 cm, to 69% for AAAs of 4.0 to 4.9 cm, 72% for AAAs of 4.0 cm or larger, and 82% for AAAs of 5.0 cm or larger. Sensitivity in subjects with an abdominal girth less than 100 cm (40-in waistline) was 91% vs 53% for girth of 100 cm or greater (P<.001). When girth was 100 cm or greater and the aorta was palpable, sensitivity was 82%. When girth was less than 100 cm and the AAA was 5.0 cm or larger, sensitivity was 100% (12 examinations). Factors independently associated with correct examination findings included AAA diameter (odds ratio [OR], 1.95 per centimeter increase; 95% CI, 1.06-3.58); abdominal girth (OR, 0.90 per centimeter increase; 95% CI, 0.87-0.94); and the examiner's assessment that the abdomen was not tight (OR, 2.68; 95% CI, 1.17-6.13).
CONCLUSIONS: Abdominal palpation has only moderate overall sensitivity for detecting AAA, but appears to be highly sensitive for diagnosis of AAAs large enough to warrant elective intervention in patients who do not have a large girth. Abdominal palpation has good sensitivity even in patients with a large girth if the aorta is palpable.
Full text links
Related Resources
Trending Papers
Challenges in Septic Shock: From New Hemodynamics to Blood Purification Therapies.Journal of Personalized Medicine 2024 Februrary 4
Molecular Targets of Novel Therapeutics for Diabetic Kidney Disease: A New Era of Nephroprotection.International Journal of Molecular Sciences 2024 April 4
Perioperative echocardiographic strain analysis: what anesthesiologists should know.Canadian Journal of Anaesthesia 2024 April 11
The 'Ten Commandments' for the 2023 European Society of Cardiology guidelines for the management of endocarditis.European Heart Journal 2024 April 18
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app