Flow convergence flow rates from 3-dimensional reconstruction of color Doppler flow maps for computing transvalvular regurgitant flows without geometric assumptions: An in vitro quantitative flow study.
Journal of the American Society of Echocardiography 1999 December
OBJECTIVE: This study was designed to develop and test a 3-dimensional method for direct measurement of flow convergence (FC) region surface area and for quantitating regurgitant flows with an in vitro flow system.
BACKGROUND: Quantitative methods for characterizing regurgitant flow events such as flow convergence with 2-dimensional color flow Doppler imaging systems have yielded variable results and may not be accurate enough to characterize those more complex spatial events.
METHOD: Four differently shaped regurgitant orifices were studied: 3 flat orifices (circular, rectangular, triangular) and a nonflat one mimicking mitral valve prolapse (all 4 orifice areas = 0.24 cm(2)) in a pulsatile flow model at 8 to 9 different regurgitant flow rates (10 to 50 mL/beat). An ultrasonic flow probe and meter were connected to the flow model to provide reference flow data. Video composite data from the color Doppler flow images of the FC were reconstructed after computer-controlled 180 degrees rotational acquisition was performed. FC surface area (S cm(2)) was calculated directly without any geometric assumptions by measuring parallel sliced flow convergence arc lengths through the FC volume and multiplying each by the slice thickness (2.5 to 3.2 mm) over 5 to 8 slices and then adding them together. Peak regurgitant flow rate (milliliters per second) was calculated as the product of 3-dimensional determined S (cm(2)) multiplied by the aliasing velocity (centimeters per second) used for color Doppler imaging.
RESULTS: For all of the 4 shaped orifices, there was an excellent relationship between actual peak flow rates and 3-dimensional FC-calculated flow rates with the direct measurement of the surface area of FC (r = 0.99, mean difference = -7.2 to -0.81 mL/s, % difference = -5% to 0%), whereas a hemielliptic method implemented with 3 axial measurements of the flow convergence zone from 2-dimensional planes underestimated actual flow rate by mean difference = -39.8 to -18.2 mL/s, % difference = -32% to -17% for any given orifice.
CONCLUSIONS: Three-dimensional reconstruction of flow based on 2-dimensional color Doppler may add quantitative spatial information, especially for complex flow events. Direct measurement of 3-dimensional flow convergence surface areas may improve accuracy for estimation of the severity of valvular regurgitation.
BACKGROUND: Quantitative methods for characterizing regurgitant flow events such as flow convergence with 2-dimensional color flow Doppler imaging systems have yielded variable results and may not be accurate enough to characterize those more complex spatial events.
METHOD: Four differently shaped regurgitant orifices were studied: 3 flat orifices (circular, rectangular, triangular) and a nonflat one mimicking mitral valve prolapse (all 4 orifice areas = 0.24 cm(2)) in a pulsatile flow model at 8 to 9 different regurgitant flow rates (10 to 50 mL/beat). An ultrasonic flow probe and meter were connected to the flow model to provide reference flow data. Video composite data from the color Doppler flow images of the FC were reconstructed after computer-controlled 180 degrees rotational acquisition was performed. FC surface area (S cm(2)) was calculated directly without any geometric assumptions by measuring parallel sliced flow convergence arc lengths through the FC volume and multiplying each by the slice thickness (2.5 to 3.2 mm) over 5 to 8 slices and then adding them together. Peak regurgitant flow rate (milliliters per second) was calculated as the product of 3-dimensional determined S (cm(2)) multiplied by the aliasing velocity (centimeters per second) used for color Doppler imaging.
RESULTS: For all of the 4 shaped orifices, there was an excellent relationship between actual peak flow rates and 3-dimensional FC-calculated flow rates with the direct measurement of the surface area of FC (r = 0.99, mean difference = -7.2 to -0.81 mL/s, % difference = -5% to 0%), whereas a hemielliptic method implemented with 3 axial measurements of the flow convergence zone from 2-dimensional planes underestimated actual flow rate by mean difference = -39.8 to -18.2 mL/s, % difference = -32% to -17% for any given orifice.
CONCLUSIONS: Three-dimensional reconstruction of flow based on 2-dimensional color Doppler may add quantitative spatial information, especially for complex flow events. Direct measurement of 3-dimensional flow convergence surface areas may improve accuracy for estimation of the severity of valvular regurgitation.
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app