We have located links that may give you full text access.
JOURNAL ARTICLE
RESEARCH SUPPORT, NON-U.S. GOV'T
Endothelial and metabolic characteristics of patients with angina and angiographically normal coronary arteries: comparison with subjects with insulin resistance syndrome and normal controls.
Journal of the American College of Cardiology 1999 November 2
OBJECTIVES: This study was performed to characterize the endothelial and metabolic alterations of patients with angina and angiographically normal coronary arteries ("cardiac" syndrome X [CSX]) compared with subjects with insulin resistance syndrome ("metabolic" syndrome X [MSX]) and normal controls.
BACKGROUND: Previous studies have found high endothelin-1 levels, impaired endothelium-dependent vasodilation and insulin resistance in patients with angina pectoris and angiographically normal coronary arteries. On the other hand, subjects with insulin resistance syndrome have shown high endothelin-1 levels.
METHODS: Thirty-five subjects were studied: 13 patients with angina pectoris and angiographically normal coronary arteries (CSX group); 9 subjects with insulin resistance syndrome (MSX group) and 13 normal controls. All subjects received an acute intravenous bolus of insulin (0.1 U/kg) combined with a euglycemic clamp and forearm indirect calorimetry. Endothelin-1 levels, nitrite/nitrate (NOx) levels, end products of nitric oxide metabolism, glucose infusion rates (index of insulin sensitivity) and their incremental areas (deltaAUCs [area under curves]) were measured during this period.
RESULTS: Basal endothelin-1 levels were higher in CSX and MSX groups than in normal controls (8.19 +/- 0.46 and 6.97 +/- 0.88 vs. 3.67 +/- 0.99 pg/ml; p < 0.01), while basal NOx levels were significantly higher in MSX group than in CSX and normal controls (36.5 +/- 4.0 vs. 24.2 +/- 3.3 and 26.8 +/- 3.2 mol/liter, p < 0.05). After insulin administration, the deltaAUCs of NOx (p < 0.05) were lower in CSX group than in MSX and normal controls, and the deltaAUCs of endothelin-1 were lower in group CSX than in normal controls. Glucose infusion rate was significantly lower in CSX and MSx groups than in normal controls (p < 0.01), suggesting that in both CSX and MSX groups insulin resistance is present. A positive correlation was found between the deltaAUCs of nitric oxide and the AUCs of glucose infusion rate.
CONCLUSIONS: Blunted nitric oxide and endothelin responsiveness to intravenously infused insulin is a typical feature of patients with angina pectoris and angiographically normal coronary arteries and may contribute to the microvascular dysfunction observed in these subjects.
BACKGROUND: Previous studies have found high endothelin-1 levels, impaired endothelium-dependent vasodilation and insulin resistance in patients with angina pectoris and angiographically normal coronary arteries. On the other hand, subjects with insulin resistance syndrome have shown high endothelin-1 levels.
METHODS: Thirty-five subjects were studied: 13 patients with angina pectoris and angiographically normal coronary arteries (CSX group); 9 subjects with insulin resistance syndrome (MSX group) and 13 normal controls. All subjects received an acute intravenous bolus of insulin (0.1 U/kg) combined with a euglycemic clamp and forearm indirect calorimetry. Endothelin-1 levels, nitrite/nitrate (NOx) levels, end products of nitric oxide metabolism, glucose infusion rates (index of insulin sensitivity) and their incremental areas (deltaAUCs [area under curves]) were measured during this period.
RESULTS: Basal endothelin-1 levels were higher in CSX and MSX groups than in normal controls (8.19 +/- 0.46 and 6.97 +/- 0.88 vs. 3.67 +/- 0.99 pg/ml; p < 0.01), while basal NOx levels were significantly higher in MSX group than in CSX and normal controls (36.5 +/- 4.0 vs. 24.2 +/- 3.3 and 26.8 +/- 3.2 mol/liter, p < 0.05). After insulin administration, the deltaAUCs of NOx (p < 0.05) were lower in CSX group than in MSX and normal controls, and the deltaAUCs of endothelin-1 were lower in group CSX than in normal controls. Glucose infusion rate was significantly lower in CSX and MSx groups than in normal controls (p < 0.01), suggesting that in both CSX and MSX groups insulin resistance is present. A positive correlation was found between the deltaAUCs of nitric oxide and the AUCs of glucose infusion rate.
CONCLUSIONS: Blunted nitric oxide and endothelin responsiveness to intravenously infused insulin is a typical feature of patients with angina pectoris and angiographically normal coronary arteries and may contribute to the microvascular dysfunction observed in these subjects.
Full text links
Trending Papers
Monitoring Macro- and Microcirculation in the Critically Ill: A Narrative Review.Avicenna Journal of Medicine 2023 July
ANCA-associated vasculitis - Treatment Standard.Nephrology, Dialysis, Transplantation 2023 November 9
ASA Consensus-based Guidance on Preoperative Management of Patients on Glucagon-like Peptide-1 Receptor Agonists.Anesthesiology 2023 November 21
Common postbariatric surgery emergencies for the acute care surgeon: What you need to know.Journal of Trauma and Acute Care Surgery 2023 December 2
How we approach titrating PEEP in patients with acute hypoxemic failure.Critical Care : the Official Journal of the Critical Care Forum 2023 October 32
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
Read by QxMD is copyright © 2021 QxMD Software Inc. All rights reserved. By using this service, you agree to our terms of use and privacy policy.
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app