Clinical Trial
Comparative Study
Journal Article
Randomized Controlled Trial
Research Support, Non-U.S. Gov't
Add like
Add dislike
Add to saved papers

Clinical effects and maternal and fetal plasma concentrations of 0.5% epidural levobupivacaine versus bupivacaine for cesarean delivery.

Anesthesiology 1999 June
BACKGROUND: Bupivacaine exists as a mixture of two enantiomers, levobupivacaine and dexbupivacaine. Data suggest that levobupivacaine has equal local anesthetic potency, with reduced potential for central nervous system and cardiovascular toxicity. The present study compares the efficacy of 0.5% levobupivacaine with 0.5% bupivacaine for epidural anesthesia in parturients undergoing elective cesarean delivery.

METHODS: Sixty healthy obstetric patients undergoing elective cesarean delivery with epidural anesthesia completed the study. Patients were randomized to receive 30 ml of either 0.5% levobupivacaine or 0.5% bupivacaine in a double-blind fashion. The efficacy endpoint measures included onset, offset, and quality of anesthesia. Neonatal blood gas analyses, Apgar score determinations, and neurobehavioral examinations were performed. Venous samples for pharmacokinetic studies and serial electrocardiograms were obtained in 10 patients in each group.

RESULTS: Levels of sensory block, motor block, muscle relaxation, and overall quality of anesthesia did not differ between groups. The frequency of hypotension was 84.4% in the levobupivacaine group and 100% for the bupivacaine group (P < or = 0.053). No significant difference in observed maximum concentration of drug after dosing or area under the plasma drug concentration versus time curve were seen. The maximum concentrations were 1.017 and 1.053 microg/ml, and the areas were 4.082 and 3.765 h(microg/ml) for the levobupivacaine and bupivacaine groups, respectively. Umbilical vein-to-maternal vein ratios were 0.303 for the levobupivacaine group and 0.254 for the bupivacaine group.

CONCLUSIONS: The use of epidural 0.5% levobupivacaine for cesarean delivery results in equally efficacious anesthesia compared with 0.5% bupivacaine. Pharmacokinetic parameters were similar in the two groups.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app