We have located links that may give you full text access.
Clinical Trial
Comparative Study
Journal Article
Nonsurgical reconstruction of thoracic aortic dissection by stent-graft placement.
New England Journal of Medicine 1999 May 20
BACKGROUND: The treatment of thoracic aortic dissection is guided by prognostic and anatomical information. Proximal dissection requires surgery, but the appropriate treatment of distal thoracic aortic dissection has not been determined, because surgery has failed to improve the prognosis.
METHODS: We prospectively evaluated the safety and efficacy of elective transluminal endovascular stent-graft insertion in 12 consecutive patients with descending (type B) aortic dissection and compared the results with surgery in 12 matched controls. In all 24 patients, aortic dissection was diagnosed by magnetic resonance angiography. In each group, the dissection involved the aortic arch in 3 patients and the descending thoracic aorta in all 12 patients. With the patient under general anesthesia, either surgical resection was undertaken or a custom-designed endovascular stent-graft was placed by unilateral arteriotomy.
RESULTS: Stent-graft placement resulted in no morbidity or mortality, whereas surgery for type B dissection was associated with four deaths (33 percent, P=0.09) and five serious adverse events (42 percent, P=0.04) within 12 months. Transluminal placement of the stent-graft prosthesis was successful in all patients, with no leakage; full expansion of the stents was ensured by balloon inflation at 2 to 3 atm. Sealing of the entry tear was monitored during the procedure by transesophageal ultrasonography and angiography, and thrombosis of the false lumen was confirmed in all 12 patients after a mean of three months by magnetic resonance imaging. There were no deaths or instances of paraplegia, stroke, embolization, side-branch occlusion, or infection in the stent-graft group; nine patients had postimplantation syndrome, with transient elevation of C-reactive protein levels and body temperature plus mild leukocytosis. All the patients who received stent-grafts recovered, as did seven patients who underwent surgery for type B dissection (58 percent) (P=0.04).
CONCLUSIONS: These preliminary observations suggest that elective, nonsurgical insertion of an endovascular stent-graft is safe and efficacious in selected patients who have thoracic aortic dissection and for whom surgery is indicated. Endoluminal repair may be useful for interventional reconstruction of thoracic aortic dissection.
METHODS: We prospectively evaluated the safety and efficacy of elective transluminal endovascular stent-graft insertion in 12 consecutive patients with descending (type B) aortic dissection and compared the results with surgery in 12 matched controls. In all 24 patients, aortic dissection was diagnosed by magnetic resonance angiography. In each group, the dissection involved the aortic arch in 3 patients and the descending thoracic aorta in all 12 patients. With the patient under general anesthesia, either surgical resection was undertaken or a custom-designed endovascular stent-graft was placed by unilateral arteriotomy.
RESULTS: Stent-graft placement resulted in no morbidity or mortality, whereas surgery for type B dissection was associated with four deaths (33 percent, P=0.09) and five serious adverse events (42 percent, P=0.04) within 12 months. Transluminal placement of the stent-graft prosthesis was successful in all patients, with no leakage; full expansion of the stents was ensured by balloon inflation at 2 to 3 atm. Sealing of the entry tear was monitored during the procedure by transesophageal ultrasonography and angiography, and thrombosis of the false lumen was confirmed in all 12 patients after a mean of three months by magnetic resonance imaging. There were no deaths or instances of paraplegia, stroke, embolization, side-branch occlusion, or infection in the stent-graft group; nine patients had postimplantation syndrome, with transient elevation of C-reactive protein levels and body temperature plus mild leukocytosis. All the patients who received stent-grafts recovered, as did seven patients who underwent surgery for type B dissection (58 percent) (P=0.04).
CONCLUSIONS: These preliminary observations suggest that elective, nonsurgical insertion of an endovascular stent-graft is safe and efficacious in selected patients who have thoracic aortic dissection and for whom surgery is indicated. Endoluminal repair may be useful for interventional reconstruction of thoracic aortic dissection.
Full text links
Related Resources
Trending Papers
Mineralocorticoid Receptor Antagonists in Heart Failure: An Update.Circulation. Heart Failure 2024 November 25
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app