keyword
https://read.qxmd.com/read/38498860/accuracy-of-dental-restorations-fabricated-using-milling-vs-3d-printed-molds-a-pilot-study
#21
JOURNAL ARTICLE
Pekka Ahlholm, Kirsi Sipilä, Pirkko-Liisa Tarvonen, Tuomo Silvast, Reijo Lappalainen
PURPOSE: To compare the accuracy of 12 different dental restorations fabricated with milling or 3D-printed molds and robotically controlled casting. MATERIALS AND METHODS: Twelve dental restorations (11 inlays and onlays and 1 crown) were made per restoration type, one per each of the 12 different teeth models (total of 24 restorations). On each tooth preparation, two restorations were manufactured using different CAD/ CAM techniques: (1) milling and (2) robotically controlled casting and 3D-printed molds...
February 21, 2024: International Journal of Prosthodontics
https://read.qxmd.com/read/38489222/comparison-of-3d-printed-single-crown-outcomes-among-different-computer-aided-design-software-programs
#22
JOURNAL ARTICLE
Juliana No-Cortes, Bonnie Attard, David Paul Mifsud, Jacqueline Ferreira Lima, Roberto Adrian Markarian, Ana Paula Ayres, Glenn Cassar, Arthur Rodriguez Gonzalez Cortes, Nikolai John Attard
PURPOSE: Low-cost resin 3D printers have been used to produce affordable interim single crowns in public and private dental practices. The purpose of this study was to assess the impact of different computer-aided design (CAD) software programs on 3D trueness, microscopic marginal and internal gaps, time to design, and interproximal contacts of low-cost 3D-printed single crowns. MATERIALS AND METHODS: This in vitro study was performed on a total of 90 standardized resin-prepared teeth adapted to a dental manikin...
February 21, 2024: International Journal of Prosthodontics
https://read.qxmd.com/read/38489220/fracture-strength-of-six-unit-anterior-fixed-provisional-restorations-fabricated-using-various-dental-cad-cam-systems
#23
JOURNAL ARTICLE
Gyu-Won Yoon, Eun-Jin Park
PURPOSE: This study compares the fracture strengths of long-span fixed provisional restorations fabricated via digital additive and subtractive methods to those fabricated via conventional heat-processing techniques. MATERIALS AND METHODS: A six-unit anterior partial restoration was designed as an anatomical and morphologic structure using a dental CAD/CAM system. The provisional restorations (N = 40) of four different fabrication methods (n = 10 per group) were used for the failure loading test: stereolithography apparatus (SLA), liquid crystal display (LCD), milling (MIL), and heat-processed temporary (HPT)...
February 21, 2024: International Journal of Prosthodontics
https://read.qxmd.com/read/38485595/clinical-performance-and-patient-related-outcome-measures-of-digitally-fabricated-complete-dentures-a-systematic-review-and-meta-analysis
#24
REVIEW
Maria Eduarda Lemos Avelino, Rayanna Thayse Florêncio Costa, Taciana Emília Leite Vila-Nova, Belmiro Cavalcanti do Egito Vasconcelos, Eduardo Piza Pellizzer, Sandra Lúcia Dantas Moraes
STATEMENT OF PROBLEM: The demand to streamline workflow while increasing patient comfort and satisfaction in the manufacturing of removable complete dentures (CDs) is growing, and computer-aided design and computer-aided manufacturing (CAD-CAM) technology has gained prominence. However, a systematic review and meta-analysis of the clinical performance and patient-related outcome measures (PROMs) of digitally fabricated complete dentures is lacking. PURPOSE: The purpose of this systematic review and meta-analysis was to determine whether digitally fabricated CDs improve the clinical performance and PROMs compared with conventionally fabricated CDs...
March 13, 2024: Journal of Prosthetic Dentistry
https://read.qxmd.com/read/38483093/flexural-properties-and-fatigue-limit-of-3d-printed-and-milled-resin-based-materials
#25
JOURNAL ARTICLE
Neimar Sartori, Said Arturo Sanchez, Dayane Oliveira, Sherif Hosney, Panagiotis Zoidis, William Martin, Luiz Gonzaga, Mateus G Rocha
PURPOSE: The purpose of this study was to evaluate the flexural strength (FS), flexural modulus (FM), and fatigue limit (FL) of 3D-printed resin-based polymers and composites and compare them to 3D-printed composites. MATERIALS AND METHODS: A bar-shaped specimen (25 × 2 × 2 mm) was CAD designed according to ISO 4049:2019, and 60 duplicates of the 3D model were nested at a 45-degree angle with the printing platform and 3D-printed with three materials: denture teeth resin (Denture Teeth, Formlabs), temporary crown and bridge resin (Temporary CB, Formlabs), and composite (Flexcera Smile Ultra+, Desktop Health)...
March 14, 2024: Journal of Prosthodontics: Official Journal of the American College of Prosthodontists
https://read.qxmd.com/read/38480018/influence-of-cad-cam-milling-strategies-on-the-outcome-of-indirect-restorations-a-scoping-review
#26
REVIEW
Rafaela Oliveira Pilecco, Renan Vaz Machry, Andrea Baldi, João Paulo Mendes Tribst, Rafael Sarkis-Onofre, Luiz Felipe Valandro, Cornelis Johannes Kleverlaan, Nicola Scotti, Gabriel Kalil Rocha Pereira
STATEMENT OF PROBLEM: The influence of computer-aided manufacturing (CAM) parameters and settings on the outcomes of milled indirect restorations is poorly understood. PURPOSE: The purpose of this scoping review was to summarize the current CAM systems, parameters, and setting changes, and their effects on different outcomes of milled indirect restorations and aspects related to their manufacture. MATERIAL AND METHODS: The protocol of this review is available online (https://osf...
March 12, 2024: Journal of Prosthetic Dentistry
https://read.qxmd.com/read/38479887/monolithic-hybrid-abutment-crowns-influence-of-crown-height-crown-morphology-and-material-on-the-implant-abutment-complex
#27
JOURNAL ARTICLE
Tobias Graf, Elisabeth Völler, Kurt Erdelt, Michael Stimmelmayr, Oliver Schubert, Jan-Frederik Güth
PURPOSE: This in vitro study investigated the influence of material selection, crown morphology, and vertical crown height on the biomechanical behavior of monolithic hybrid abutment crowns (HACs). METHODS: Ninety implants were embedded in accordance with ISO standard 14801; ninety HACs were mounted (N=90). Monolithic crowns with varying group-specific designs were luted using titanium bases. HACs were fabricated from monolithic lithium disilicate ceramic (LD) or zirconia-reinforced lithium silicate ceramic (ZLS)...
March 13, 2024: Journal of Prosthodontic Research
https://read.qxmd.com/read/38477845/occlusal-veneers-and-load-bearing-capacity-of-a-restored-tooth
#28
JOURNAL ARTICLE
Topias Yli-Urpo, Lippo Lassila, Timo Närhi, Pekka Vallittu
PURPOSE: The aim of this study was to evaluate the influence of restoration bonding and type of preparation on load bearing capacity of a tooth restored with indirect glass ceramic or hybrid ceramic occlusal veneer restoration. MATERIALS AND METHODS: Occlusal surfaces of extracted human molar teeth were prepared for indirect occlusal veneers with or without circumferential chamfer. The occlusal veneers were milled either from CAD/CAM hybrid ceramic (HC) Cerasmart (GC), or lithium-disilicate glass ceramic (LDGC) IPS e...
March 13, 2024: International Journal of Prosthodontics
https://read.qxmd.com/read/38455677/clinical-comparison-of-marginal-fit-of-ceramic-inlays-between-digital-and-conventional-impressions
#29
JOURNAL ARTICLE
Franklin Guillermo Vargas-Corral, Américo Ernesto Vargas-Corral, Miguel Angel Rodríguez Valverde, Manuel Bravo, Juan Ignacio Rosales Leal
PURPOSE: The aim of this stuldy was to compare the clinical marginal fit of CAD-CAM inlays obtained from intraoral digital impression or addition silicone impression techniques. MATERIALS AND METHODS: The study included 31 inlays for prosthodontics purposes of 31 patients: 15 based on intraoral digital impressions (DI group); and 16 based on a conventional impression technique (CI group). Inlays included occlusal and a non-occlusal surface. Inlays were milled in ceramic...
February 2024: Journal of Advanced Prosthodontics
https://read.qxmd.com/read/38455676/3d-quantitative-analysis-and-sem-qualitative-analysis-of-natural-antagonist-enamel-opposing-cad-cam-monolithic-zirconia-or-lithium-disilicate-tooth-supported-crowns-versus-enamel-opposing-natural-enamel
#30
JOURNAL ARTICLE
Piyarat Woraganjanaboon, Chuchai Anunmana
PURPOSE: This study aimed to evaluate the maximum vertical wear, volume wear, and surface characteristic of antagonist enamel, opposing monolithic zirconia or lithium disilicate crowns. MATERIALS AND METHODS: The study comprised 24 participants (n = 12), who were randomly allocated to receive either a 5 mol% Y-TZP or a lithium disilicate crown in positions which would oppose the natural first molar tooth. The contralateral first molar along with its antagonist was considered as the enamel opposing natural enamel control...
February 2024: Journal of Advanced Prosthodontics
https://read.qxmd.com/read/38443240/in-vitro-damping-and-strain-distribution-for-implant-supported-crowns-using-5-different-cad-cam-crowns-and-3-different-luting-cements
#31
JOURNAL ARTICLE
Charnikan Sukkasam, Krid Kamonkhantikul, Woraporn Homsiang, Mansuang Arksornnukit
STATEMENT OF PROBLEM: Dental implants are particularly susceptible to occlusal overloading because, unlike natural teeth, they lack a periodontal ligament to help absorb occlusal forces. However, studies evaluating the impact of different crown and luting materials on the damping behavior and strain distribution of implant-supported crowns are lacking. PURPOSE: The purpose of this in vitro study was to investigate the damping behavior and strain distribution of peri-implant bone associated with 5 different CAD-CAM implant-supported crowns and 3 luting materials...
March 4, 2024: Journal of Prosthetic Dentistry
https://read.qxmd.com/read/38439020/adhesion-of-candida-albicans-to-digital-versus-conventional-acrylic-resins-a-systematic-review-and-meta-analysis
#32
JOURNAL ARTICLE
Mohammed Nasser Alhajj, Esam Halboub, Norlela Yacob, Sadeq Ali Al-Maweri, Siti Fauzza Ahmad, Asja Celebić, Hesham M Al-Mekhlafi, Nosizana Mohd Salleh
BACKGROUND: The present systematic review and meta-analysis investigated the available evidence about the adherence of Candida Albicans to the digitally-fabricated acrylic resins (both milled and 3D-printed) compared to the conventional heat-polymerized acrylic resins. METHODS: This study followed the guidelines of the Preferred Reporting Items for Systematic Review and Meta-analyses (PRISMA). A comprehensive search of online databases/search tools (Web of Science, Scopus, PubMed, Ovid, and Google Scholar) was conducted for all relevant studies published up until May 29, 2023...
March 4, 2024: BMC Oral Health
https://read.qxmd.com/read/38431509/effect-of-surface-roughness-and-biofilm-formation-on-the-color-properties-of-resin-infiltrated-ceramic-and-lithium-disilicate-glass-ceramic-cad-cam-materials
#33
JOURNAL ARTICLE
Sümeyra Topçu, Neslihan Tekçe, Dilan Kopuz, Eda Yazıcı Özcelik, Fetiye Kolaylı, Safa Tuncer, Mustafa Demirci
STATEMENT OF PROBLEM: Computer-aided design and computer-aided manufacturing (CAD-CAM) materials have become popular for dental restorations; however, which materials should be preferred in terms of surface properties after biofilm formation is unclear. PURPOSE: The purpose of this in vitro study was to investigate the effect of biofilm formation on the discoloration properties of resin-infiltrated ceramic and glass ceramic CAD-CAM materials and human teeth and to examine the effect of the brushing procedure on color change...
March 1, 2024: Journal of Prosthetic Dentistry
https://read.qxmd.com/read/38416007/vascular-delay-soft-tissue-technique-in-oral-maxillary-bone-reconstructive-surgery-a-technical-note
#34
JOURNAL ARTICLE
Federico Hernández-Alfaro, Adaia Valls-Ontañón, Jorge Bertos-Quílez, Maria Giralt-Hernando, Gian Maria Ragucci
PURPOSE: The present study describes a new presurgical soft tissue technique in oral/maxillary bone reconstructive surgery for reducing the risk of soft tissue dehiscence and its related complications. MATERIALS AND METHODS: Ten consecutive patients with Cawood and Howell type V atrophy were scheduled for CAD/CAM titanium mesh bone reconstructive surgery after applying the vascular delay technique 21 days before regenerative surgery. The surgical and healing complications were clinically assessed at nine time points, ranging from the time of bone regenerative surgery to 9 months after surgery...
February 27, 2024: International Journal of Oral & Maxillofacial Implants
https://read.qxmd.com/read/38403847/denture-relining-using-digital-replication-method-a-dental-technique
#35
JOURNAL ARTICLE
Mohammed M Gad, Haidar Alalawi, Faisal D Al-Qarni, Fahad A Al-Harbi
The aim of this report was to digitize traditional denture relining using a digital duplication method, in addition to assessing the wear resistance of three-dimensional (3D) printed denture teeth. A complete denture was relined using light body impression. The denture with impression was scanned yielding a standard tessellation language file that was designed to print the denture base and teeth. The printed teeth were fitted into the sockets of the printed denture base and then bonded using auto-polymerized acrylic resins, followed by finishing and polishing...
February 25, 2024: Journal of Prosthodontics: Official Journal of the American College of Prosthodontists
https://read.qxmd.com/read/38402388/assessment-of-knowledge-and-practices-of-additive-manufacturing-in-dentistry-among-university-teaching-faculty-in-saudi-arabia
#36
JOURNAL ARTICLE
Khalid K Alanazi, Abdulaziz A Alzaid, Adel Alotaibi, Nora Almehisni, Ghida Alzahrani, Khalid Gufran
BACKGROUND: In recent era, digitalization in the dental sciences has been observed in wide ranges. This cross-sectional study aimed to assess knowledge and practice of additive manufacturing (AM) in dentistry among university teaching faculty in Saudi Arabia. METHODS: A questionnaire was prepared and validated to distribute to the different dental colleges in Saudi Arabia. The questionnaire was divided into three parts: demographic information, knowledge and practices of AM among the dental teaching faculty...
February 24, 2024: BMC Oral Health
https://read.qxmd.com/read/38392236/effect-of-duplication-techniques-on-the-fitting-accuracy-of-cad-cam-milled-3d-printed-and-injection-molded-mandibular-complete-denture-bases
#37
JOURNAL ARTICLE
Abdel-Naser M Emam, Ahmed Ayman El-Esawy, Mohammed Hamad Alyami, Yasser Baraka, Mohammed M Gad, Mohamed Ahmed Helal
BACKGROUND: Digital technology has been introduced in prosthodontics, and it has been widely used in denture duplication instead of a conventional denture duplication technique. However, research comparing different denture duplication techniques and how they affect the fitting accuracy of the denture base is scarce. OBJECTIVES: The aim was to assess the impact of duplication techniques on the accuracy of the fitting surface of computer-aided design and manufacturing (CAD-CAM) milled, 3D-printed, and injection-molded complete denture bases (CDBs)...
February 2, 2024: Dentistry Journal
https://read.qxmd.com/read/38381998/-effect-of-aging-on-the-mechanical-properties-of-cad-cam-milled-and-3d-printed-acrylic-resins-for-denture-bases
#38
JOURNAL ARTICLE
Victor A A Bento, Jessica M L Gomes, João P J Oliveira-Limirio, Cleber D D R D Rosa, Cleidiel A A Lemos, Daniela M Dos Santos, Eduardo P Pellizzer
PURPOSE: The purpose of this study was to investigate the mechanical properties of acrylic resins at different aging times for denture bases manufactured using the conventional method, microwave processing, milling, and 3D printing. MATERIALS AND METHODS: A total of 160 rectangular samples (64 Å~ 10 Å~ 3.3 ± 0.03 mm) were prepared, divided among the four main resin groups, and subdivided into four analysis times (T0, T1, T2, and T3), resulting in 10 samples per subgroup...
February 21, 2024: International Journal of Prosthodontics
https://read.qxmd.com/read/38381993/marginal-fit-and-internal-adaptation-of-monolithic-zirconia-3-unit-fixed-dental-prosthesis-in-vitro-study
#39
JOURNAL ARTICLE
Nuha A Alkaff, Dorin N Ruse, Kevin Aminzadeh, Alan G Hannam, Nesrine Mostafa
PURPOSE: To compare the marginal and internal fit of monolithic zirconia (MZ) 3-unit fixed dental prostheses (FDPs) fabricated using two CAD/CAM workflows: full-chairside (FCH) and lab (LAB). MATERIALS AND METHODS: The right maxillary first premolar and first molar were prepared for MZ 3-unit FDPs on a typodont. CEREC Primescan digitized the typodont model 15 Omes. A total of 30 FDPs was fabricated using two processes: FCH (n = 15) and LAB (n = 15). FCH and LAB FDPs were designed using CEREC SW 4...
February 21, 2024: International Journal of Prosthodontics
https://read.qxmd.com/read/38381992/accuracy-of-occlusal-contacts-of-all-ceramic-single-crowns-designed-by-virtual-articulators-from-a-cad-cam-system-a-preliminary-evaluation
#40
JOURNAL ARTICLE
Yun Yuan, Enxin Xu, Xinrui Xu, Hui Huang
PURPOSE: To compare the static and dynamic occlusion of all-ceramic single crowns designed by mechanical and virtual articulators, by evalua6ng the accuracy of occlusal contacts of prostheses designed by virtual articulators and the feasibility of clinical application of CAD/CAM virtual articulators. MATERIALS AND METHODS: Nine subjects with an average age of 27 years who needed crown repair were recruited. After preparation of the all-ceramic crowns, two zirconia crowns were designed and fabricated through digital procedures and traditional methods...
February 21, 2024: International Journal of Prosthodontics
keyword
keyword
92969
2
3
Fetch more papers »
Fetching more papers... Fetching...
Remove bar
Read by QxMD icon Read
×

Save your favorite articles in one place with a free QxMD account.

×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"

We want to hear from doctors like you!

Take a second to answer a survey question.