keyword
https://read.qxmd.com/read/38751729/open-source-graphical-user-interface-for-the-creation-of-synthetic-skeletons-for-medical-image-analysis
#1
JOURNAL ARTICLE
Christian Herz, Nicolas Vergnet, Sijie Tian, Abdullah H Aly, Matthew A Jolley, Nathanael Tran, Gabriel Arenas, Andras Lasso, Nadav Schwartz, Kathleen E O'Neill, Paul A Yushkevich, Alison M Pouch
PURPOSE: Deformable medial modeling is an inverse skeletonization approach to representing anatomy in medical images, which can be used for statistical shape analysis and assessment of patient-specific anatomical features such as locally varying thickness. It involves deforming a pre-defined synthetic skeleton, or template, to anatomical structures of the same class. The lack of software for creating such skeletons has been a limitation to more widespread use of deformable medial modeling...
May 2024: Journal of Medical Imaging
https://read.qxmd.com/read/38748674/evaluation-of-the-horizontal-approach-to-the-medial-malleolar-facet-in-sagittal-talar-fractures-through-dorsiflexion-and-plantarflexion-positions
#2
JOURNAL ARTICLE
Xian Li, Xiao-Ke Wang, Li-Ren Han, Hao Li, Hui-Chao Tian, Jun Yan, Hai-Juan Liu
BACKGROUND: Talar fractures often require osteotomy during surgery to achieve reduction and screw fixation of the fractured fragments due to limited visualization and operating space of the talar articular surface. The objective of this study was to evaluate the horizontal approach to the medial malleolus facet by maximizing exposure through dorsiflexion and plantarflexion positions. METHODS: In dorsiflexion, plantarflexion, and functional foot positions, we respectively obtained the anterior and posterior edge lines of the projection of the medial malleolus on the medial malleolar facet...
2024: PloS One
https://read.qxmd.com/read/38747532/improving-standard-volar-plate-fixation-in-3d-guided-corrective-osteotomy-of-the-distal-radius-evaluation-of-a-shim-instrument
#3
JOURNAL ARTICLE
Emilia Gryska, Katleen Libberecht, Charlotte Stor Swinkels, Peter Axelsson, Per Fredrikson, Anders Björkman
Standard volar plates often do not fit the surface of the malunited distal radius after osteotomy, necessitating an offset angle for accurate volar tilt correction. The correction can be achieved if the plate is held at the correct angle when the distal screws are locked. With the advantage of 3D surgical planning and patient-specific instruments, we developed a shim instrument to assist the surgeon in securing the plate at the intended angle when locking the distal screws, and evaluated radiological results...
May 15, 2024: Journal of Plastic Surgery and Hand Surgery
https://read.qxmd.com/read/38746485/from-data-to-design-constructing-scapula-and-hip-bone-through-online-datasets-open-source-software-and-3d-printers
#4
JOURNAL ARTICLE
Dharam S Rathia, Vijay K Konuri
Introduction Human skeletons and bones are essential for medical and allied sciences students. Nowadays, it is becoming challenging to procure bone legally, resulting in medical students' inadequacy of bone. Plaster-of-Paris or resin bone models sold on the market are less detailed than real bones. Aims and objectives This study aims to create a three-dimensional (3D)-printed human bone model with free, open-source software and fused deposition modelling (FDM) 3D printers, compare its accuracy with the original bones and validate it with a textbook description...
May 2024: Curēus
https://read.qxmd.com/read/38746409/assessment-of-3d-hemi-diaphragmatic-motion-via-free-breathing-dynamic-mri-in-pediatric-thoracic-insufficiency-syndrome
#5
Mahdie Hosseini, Jayaram K Udupa, You Hao, Yubing Tong, Caiyun Wu, Yusuf Akhtar, Mostafa Al-Noury, Shiva Shaghaghi, Joseph M McDonough, David M Biko, Samantha Gogel, Oscar H Mayer, Patrick J Cahill, Drew A Torigian, Jason B Anari
PURPOSE: Thoracic insufficiency syndrome (TIS) affects ventilatory function due to spinal and thoracic deformities limiting lung space and diaphragmatic motion. Corrective orthopedic surgery can be used to help normalize skeletal anatomy, restoring lung space and diaphragmatic motion. This study employs free-breathing dynamic MRI (dMRI) and quantifies the 3D motion of each hemi-diaphragm surface in normal and TIS patients, and evaluates effects of surgical intervention. MATERIALS AND METHODS: In a retrospective study of 149 pediatric patients with TIS and 190 healthy children, we constructed 4D images from free-breathing dMRI and manually delineated the diaphragm at end-expiration (EE) and end-inspiration (EI) time points...
May 3, 2024: medRxiv
https://read.qxmd.com/read/38745863/dense-surface-reconstruction-using-a-learning-based-monocular-vslam-model-for-laparoscopic-surgery
#6
JOURNAL ARTICLE
James Yu, Kelden Pruitt, Nati Nawawithan, Brett A Johnson, Jeffrey Gahan, Baowei Fei
Augmented reality (AR) has seen increased interest and attention for its application in surgical procedures. AR-guided surgical systems can overlay segmented anatomy from pre-operative imaging onto the user's environment to delineate hard-to-see structures and subsurface lesions intraoperatively. While previous works have utilized pre-operative imaging such as computed tomography or magnetic resonance images, registration methods still lack the ability to accurately register deformable anatomical structures without fiducial markers across modalities and dimensionalities...
February 2024: Proceedings of SPIE
https://read.qxmd.com/read/38745014/experimental-study-on-the-punching-failure-model-of-soft-red-rock-subgrade-by-bpt-bvm-methods-and-it-s-assessment-of-the-load-bearing-capacity
#7
JOURNAL ARTICLE
Jibin Chen, Qiang Pan, Yao Wei, Yibin Luo, Zhuangfu Zhao, Li Zhao, Yu Bai
The recommended bearing capacity of medium weathering mudstone foundation is less than the capacity of the rock structure to withstand loads in Southwest China. A comprehensive failure characterization of medium weathering mudstone in Chengdu has been performed including bearing plate test (BPT), binocular vision measurement (BVM) test, uniaxial compressive strength test, trial trench test of shallow rock surface and 3D imaging in this paper. Failure behavior of rock has been modeled with 3D imaging algorithm that utilizes Zhang's calibration method in BVM system combination with trial trench test of shallow rock surface...
May 14, 2024: Scientific Reports
https://read.qxmd.com/read/38744300/cardiac-mri-segmentation-using-shifted-window-multilayer-perceptron-mixer-networks
#8
JOURNAL ARTICLE
Elham Abouei, Shaoyan Pan, Mingzhe Hu, Aparna H Kesarwala, Richard L J Qiu, Jun Zhou, Justin Roper, Xiaofeng Yang
In this work, we proposed a deep-learning segmentation algorithm for cardiac magnetic resonance imaging (MRI) to aid in contouring of the left ventricle (LV), right ventricle (RV), and Myocardium (Myo). 
Methods: We proposed a shifted window multilayer perceptron (Swin-MLP) mixer network which is built upon a 3D U-shaped symmetric encoder-decoder structure. We evaluated our proposed network using public data from 100 individuals. The network performance was quantitatively evaluated using 3D volume similarity between the ground truth contours and the predictions using Dice score coefficient, sensitivity, and precision as well as 2D surface similarity using Hausdorff distance (HD), mean surface distance (MSD) and residual mean square distance (RMSD)...
May 14, 2024: Physics in Medicine and Biology
https://read.qxmd.com/read/38743608/on-presentation-of-cerebral-arteries-via-cortical-openings
#9
JOURNAL ARTICLE
Wieslaw L Nowinski
The presentation of cortical arteries is challenging, as most of their course is hidden in the depth of the sulci. Despite that, demonstrating the arteries on the cortical surface is a standard way of their presentation. To keep advantages of surface presentation while lessening its limitation, we propose a novel context-related method of cerebrovasculature presentation by cortical openings consisting in the removal of a selected region from the cortical mantle and exposing underlying structures. We also introduce a reverse than standard vessel-to-context mapping from a gyrus/lobule to vessels supplying it...
May 14, 2024: Neuroradiology Journal
https://read.qxmd.com/read/38741372/combustion-characteristics-of-vat-photopolymerized-fuels-with-a-spiral-star-port-for-hybrid-propulsion
#10
JOURNAL ARTICLE
Qihang Chen, Xiaolong Fu, Weitao Yang, Rui Hu, Lianpeng Cui, Saiqin Meng
Despite hybrid rocket motors offering distinct advantages over solid or liquid rocket motors, their low regression rate and insufficient combustion efficiency remain significantly unimproved. This study focuses on the effects of the helix lead on the regression rate distribution and combustion efficiency of vat-polymerized fuel grains with a spiral star port for a hybrid rocket. Both experimental and numerical investigations were conducted to study the combustion characteristics and regression rate distribution of three-dimensional (3D) print grains...
May 13, 2024: Langmuir: the ACS Journal of Surfaces and Colloids
https://read.qxmd.com/read/38739500/designing-a-virtual-toolkit-for-analysing-planetary-science-data-in-virtual-reality
#11
JOURNAL ARTICLE
Helen C Miles, Andra Jones
To understand the surface evolution and potential habitability of other planets we must analyse their geology - the 3D structure and chemistry of the rocks that are exposed at the surface. Although rovers capture this 3D structure using stereo camera systems and other instruments, when we present this information to mission scientists for analysis it is generally confined to the 2D plane of a computer screen, and the spatial information is lost at the point when it is needed most. To address this problem, we design, develop, and evaluate a prototype Virtual Environment to present geological data in the 3D form in which it was originally captured, and users are supplied with a toolkit for measurement and annotation of data...
May 13, 2024: IEEE Transactions on Visualization and Computer Graphics
https://read.qxmd.com/read/38738893/microhardness-measurements-on-tooth-and-alveolar-bone-in-rodent-oral-disease-models
#12
JOURNAL ARTICLE
Motoki Okamoto, Shohei Yamashita, Takumi Memida, Melanie Mendonca, Susanne Brueckner, Shin Nakamura, Satoru Shindo, Ria Achong-Bowe, Jeffrey Thompson, Xiaozhe Han, Toshihisa Kawai, Maiko Suzuki
The mechanical property, microhardness, is evaluated in dental enamel, dentin, and bone in oral disease models, including dental fluorosis and periodontitis. Micro-CT (µCT) provides 3D imaging information (volume and mineral density) and scanning electron microscopy (SEM) produces microstructure images (enamel prism and bone lacuna-canalicular). Complementarily to structural analysis by µCT and SEM, microhardness is one of the informative parameters to evaluate how structural changes alter mechanical properties...
April 26, 2024: Journal of Visualized Experiments: JoVE
https://read.qxmd.com/read/38735036/evaluation-and-3d-imaging-of-mineral-structure-changes-of-the-rabbit-new-zealand-skull-during-developmental-periods
#13
JOURNAL ARTICLE
Yeşim Aslan Kanmaz, Saime Betül Baygeldi, Barış Can Güzel, Yücehan Yılmaz, Meryem Karan, Betül Dağoğlu Hark, Sadık Yılmaz
This study aimed to determine the morphometric measurements anatomically and CT images of skulls of healthy male and female rabbits during postnatal development, to analyse the data statistically and to demonstrate the structural changes in bone. A total of 40 rabbits (20 females and 20 males) were divided into four groups including prepubertal period (group I (0-1 month)), period between adolescence and adulthood (group II (3-5 month)) and later (young adult period as group III (1-3 years) and old adult period as group IV (3-5 years)), with five animals in each group...
May 2024: Anatomia, Histologia, Embryologia
https://read.qxmd.com/read/38730187/a-fully-automatic-fiducial-detection-and-correspondence-establishing-method-for-online-c-arm-calibration
#14
JOURNAL ARTICLE
Wenyuan Sun, Xiaoyang Zou, Guoyan Zheng
PURPOSE: Online C-arm calibration with a mobile fiducial cage plays an essential role in various image-guided interventions. However, it is challenging to develop a fully automatic approach, which requires not only an accurate detection of fiducial projections but also a robust 2D-3D correspondence establishment. METHODS: We propose a novel approach for online C-arm calibration with a mobile fiducial cage. Specifically, a novel mobile calibration cage embedded with 16 fiducials is designed, where the fiducials are arranged to form 4 line patterns with different cross-ratios...
May 10, 2024: International Journal of Computer Assisted Radiology and Surgery
https://read.qxmd.com/read/38729983/a-three-dimensional-algorithm-for-precise-measurement-of-human-auricle-parameters
#15
JOURNAL ARTICLE
Yangyang Lin, Johannes G G Dobbe, Nadia Lachkar, Elsa M Ronde, Theo H Smit, Corstiaan C Breugem, Geert J Streekstra
Measurement of auricle parameters for planning and post-operative evaluation presents substantial challenges due to the complex 3D structure of the human auricle. Traditional measurement methods rely on manual techniques, resulting in limited precision. This study introduces a novel automated surface-based three-dimensional measurement method for quantifying human auricle parameters. The method was applied to virtual auricles reconstructed from Computed Tomography (CT) scans of a cadaver head and subsequent measurement of important clinically relevant aesthetical auricular parameters (length, width, protrusion, position, auriculocephalic angle, and inclination angle)...
May 10, 2024: Scientific Reports
https://read.qxmd.com/read/38729810/color-flow-ultrasound-spatial-sampling-beam-density-for-partial-volume-corrected-three-dimensional-volume-flow-3dvf-theory-simulation-and-experiment
#16
JOURNAL ARTICLE
Stephen Z Pinter, Jonathan M Rubin, Anne L Hall, J Brian Fowlkes, Oliver D Kripfgans
OBJECTIVE: The purpose of this study was to quantify the accuracy of partial volume-corrected three-dimensional volume flow (3DVF) measurements as a function of spatial sampling beam density using carefully-designed parametric analyses in order to inform the target applications of 3DVF. METHODS: Experimental investigations employed a mechanically-swept curvilinear ultrasound array to acquire 3D color flow (6.3 MHz) images in flow phantoms consisting of four lumen diameters (6...
May 9, 2024: Ultrasound in Medicine & Biology
https://read.qxmd.com/read/38725875/exploratory-investigation-of-virtual-lesions-in-gastrointestinal-endoscopy-using-a-novel-phase-shift-method-for-three-dimensional-shape-measurement
#17
JOURNAL ARTICLE
Taku Sakamoto, Ichiro Oda, Takuma Okamura, Hourin Cho, Naoya Toyoshima, Satoru Nonaka, Haruhisa Suzuki, Tatsuya Nakamura, Daichi Watanabe, Keigo Matsuo, Kazunari Hanano, Tetsuhide Takeyama, Shigetaka Yoshinaga, Yutaka Saito
Accurate measurement of the size of lesions or distances between any two points during endoscopic examination of the gastrointestinal tract is difficult owing to the fisheye lens used in endoscopy. To overcome this issue, we developed a phase-shift method to measure three-dimensional (3D) data on a curved surface, which we present herein. Our system allows the creation of 3D shapes on a curved surface by the phase-shift method using a stripe pattern projected from a small projecting device to an object...
April 2025: DEN Open
https://read.qxmd.com/read/38720863/the-rupture-risk-of-intracranial-saccular-aneurysm-a-case-control-study-based-on-a-three-dimensional-computed-tomography-angiography-model
#18
JOURNAL ARTICLE
Yueyun Chen, Jiayang Wu, Wenxia Yuan, Wenfeng Mai, Hengguo Li
BACKGROUND: Assessing the risk of rupture in intracranial aneurysms is crucial. Advancements in medical imaging now allow for three-dimensional (3D) assessments of aneurysms, providing a more detailed understanding of their morphology and associated risks. This study aimed to compare the 3D morphological parameters of ruptured and unruptured intracranial saccular aneurysms (ISAs) using computed tomography angiography (CTA) and to analyze risk factors linked to ISA rupture. METHODS: This retrospective case-control study included patients diagnosed with ISAs via CTA, for which data were sourced from both the Emergency Department and Inpatient Unit in The First Affiliated Hospital of Jinan University...
May 1, 2024: Quantitative Imaging in Medicine and Surgery
https://read.qxmd.com/read/38718759/a-novel-3d-high-resolution-imaging-method-using-correlative-x-ray-and-electron-microscopy-to-study-nd-yag-laser-induced-defects-in-intraocular-lenses
#19
JOURNAL ARTICLE
Andreas F Borkenstein, Adrian Mikitisin, Alexander Schwedt, Eva-Maria Borkenstein, Joachim Mayer
INTRODUCTION: Cataract extraction is the most frequently performed ophthalmological procedure worldwide. Posterior capsule opacification (PCO) remains the most common consequence after cataract surgery and can lead to deterioration of the visual performance with cloudy, blurred vision and halo, glare effects. Nd:YAG laser capsulotomy is the gold standard treatment and a very effective, safe and fast procedure in removing the cloudy posterior capsule. Damaging the intraocular lens during the treatment may occur due to wrong focus of the laser beam...
May 8, 2024: Ophthalmic Research
https://read.qxmd.com/read/38714280/in-situ-biosynthesized-plant-exudate-gums%C3%A2-silver-nanocomposites-as-corrosion-inhibitors-for-mild-steel-in-hydrochloric-acid-medium
#20
JOURNAL ARTICLE
Ukeme J Timothy, Ukashat Mamudu, Moses M Solomon, Peace S Umoren, Isaac O Igwe, Placid I Anyanwu, Bibiana C Aharanwa, Ren Chong Lim, Theresa O Uchechukwu, Saviour A Umoren
Natural gums due to availability, multifunctionality, and nontoxicity are multifaceted in application. In corrosion inhibition applications, their performance, in unmodified form is unsatisfactory because of high hydration rate, solubility issues, algal and microbial contamination, as well as thermal instability. This work attempts to enhance the inhibitive performance of Berlinia grandiflora (BEG) and cashew (CEG) exudate gums through various modification approaches. The potential of biogenic BEG and CEG gums-silver (Ag) nanocomposites (NCPs) for corrosion inhibition of mild steel in 1 M HCl is studied...
May 5, 2024: International Journal of Biological Macromolecules
keyword
keyword
84325
1
2
Fetch more papers »
Fetching more papers... Fetching...
Remove bar
Read by QxMD icon Read
×

Save your favorite articles in one place with a free QxMD account.

×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"

We want to hear from doctors like you!

Take a second to answer a survey question.