keyword
https://read.qxmd.com/read/38604185/deep-learning-for-high-resolution-dose-prediction-in-high-dose-rate-brachytherapy-for-breast-cancer-treatment
#21
JOURNAL ARTICLE
Sébastien Quetin, Boris Bahoric, Farhad Maleki, Shirin A Enger
Monte Carlo (MC) simulations are the benchmark for accurate radiotherapy dose calculations, notably in patient-specific high dose rate brachytherapy (HDR BT), in cases where considering tissue heterogeneities is critical. However, the lengthy computational time limits the practical application of MC simulations. Prior research used Deep Learning (DL) for dose prediction as an alternative to MC simulations. While accurate dose predictions akin to MC were attained, GPU limitations constrained these predictions to large voxels of 3mm × 3mm × 3mm...
April 11, 2024: Physics in Medicine and Biology
https://read.qxmd.com/read/38591989/evaluating-omadacycline-dosing-regimens-against-drug-resistant-pathogens-including-staphylococcus-aureus-streptococcus-pneumoniae-and-haemophilus-influenzae-in-adults-a-pharmacokinetic-pharmacodynamic-analysis-using-monte-carlo-simulation
#22
JOURNAL ARTICLE
Xiao-Chen Wei, Ming-Feng Zhao, Xia Xiao
The objective of this study was to evaluate the efficacy of various dosing regimens of omadacycline against main drug-resistant pathogens in the treatment of acute bacterial skin and skin structure infections (ABSSSI) and community-acquired bacterial pneumonia (CABP). Monte Carlo simulations were conducted using pharmacokinetic parameters and pharmacodynamic data to calculate cumulative fractions of response (CFRs) in terms of drug area under the concentration curve/minimum inhibition concentration targets...
April 9, 2024: Journal of Chemotherapy
https://read.qxmd.com/read/38588509/dose-rate-conversion-coefficients-for-ocular-contamination-in-nuclear-medicine-a-monte-carlo-simulation-with-experimental-validation
#23
JOURNAL ARTICLE
Eva J I Hoeijmakers, Kes Hoenen, Matthias Bauwens, Daniëlle B P Eekers, Cécile R L P N Jeukens, Roel Wierts
BACKGROUND: Since 2011, the International Commission on Radiological Protection (ICRP) has recommended an annual eye lens dose limit of 20 mSv for radiation workers, averaged over 5 years, with no year exceeding 50 mSv. However, limited research has been conducted on dose rate conversion coefficients (DCCs) for direct contamination of the eye. PURPOSE: This study aimed to accurately determine DCCs for the eye lens and cornea for ocular contamination with radionuclides used in nuclear medicine...
April 8, 2024: Medical Physics
https://read.qxmd.com/read/38588477/estimation-of-the-relative-biological-effectiveness-for-double-strand-break-induction-of-clinical-kilovoltage-beams-using-monte-carlo-simulations
#24
JOURNAL ARTICLE
Oran McElligott, Mihails Nikandrovs, Patrick McCavana, Brendan McClean, Luis León Vintró
BACKGROUND: The Relative Biological Effectiveness (RBE) of kilovoltage photon beams has been previously investigated in vitro and in silico using analytical methods. The estimated values range from 1.03 to 1.82 depending on the methodology and beam energies examined. PURPOSE: The focus of this work was to independently estimate RBE values for a range of clinically used kilovoltage beams (70-200 kVp) while investigating the suitability of using TOPAS-nBio for this task...
April 8, 2024: Medical Physics
https://read.qxmd.com/read/38577564/a-novel-method-to-derive-a-human-safety-limit-for-pfoa-by-gene-expression-profiling-and-modelling
#25
JOURNAL ARTICLE
Arthur de Carvalho E Silva, George D Loizou, Kevin McNally, Olivia Osborne, Claire Potter, David Gott, John K Colbourne, Mark R Viant
Perfluorooctanoic acid (PFOA) is a persistent environmental contaminant that can accumulate in the human body due to its long half-life. This substance has been associated with liver, pancreatic, testicular and breast cancers, liver steatosis and endocrine disruption. PFOA is a member of a large group of substances also known as "forever chemicals" and the vast majority of substances of this group lack toxicological data that would enable their effective risk assessment in terms of human health hazards. This study aimed to derive a health-based guidance value for PFOA intake (ng/kg BW/day) from in vitro transcriptomics data...
2024: Frontiers in toxicology
https://read.qxmd.com/read/38570400/monte-carlo-simulation-study-on-the-dose-and-dose-averaged-linear-energy-transfer-distributions-in-carbon-ion-radiotherapy
#26
JOURNAL ARTICLE
Akihisa Ishikawa, Yusuke Koba, Takuya Furuta, Weishan Chang, Shunsuke Yonai, Shinnosuke Matsumoto, Shintaro Hashimoto, Yuta Hirai, Tatsuhiko Sato
Dose-averaged linear energy transfer (LETd ) is conventionally evaluated from the relative biological effectiveness (RBE)-LETd fitted function used in the treatment planning system. In this study, we calculated the physical doses and their linear energy transfer (LET) distributions for patterns of typical CIRT beams using Monte Carlo (MC) simulation. The LETd was then deduced from the MC simulation and compared with that obtained from the conventional method. The two types of LETd agreed well with each other, except around the distal end of the spread-out Bragg peak...
April 3, 2024: Radiological Physics and Technology
https://read.qxmd.com/read/38552877/in-vitro-activity-pharmacodynamic-profile-and-dose-optimization-of-biapenem-against-ndm-and-oxa-48-like-carbapenemase-producing-klebsiella-pneumoniae-a-multicenter-study-in-thailand
#27
JOURNAL ARTICLE
Worapong Nasomsong, Chirakhana Siangtrong, Parnrada Nulsopapon, Supanun Pungcharoenkijkul, Patcharapa Boonmee, Wichai Santimaleeworagun
BACKGROUND: Biapenem (BIPM) exhibited a less efficient substrate for various Metallo-β-lactamase (MBL) than other carbapenems. OBJECTIVE: We aimed to evaluate in vitro susceptibility data of BIPM, and optimal dose based on Monte Carlo simulation to extend treatment options. METHODS: We collected 192 carbapenem-resistant Klebsiella pneumoniae (CRKP) clinical isolates from unique patients among multicenters in Thailand, from June 2019-March 2023...
March 27, 2024: Journal of Global Antimicrobial Resistance
https://read.qxmd.com/read/38544867/variation-of-the-relative-biological-effectiveness-in-the-penumbra-of-ion-therapy-beams-estimated-using-different-microdosimetric-approaches
#28
JOURNAL ARTICLE
Alessio Parisi, Keith M Furutani, Chris J Beltran
BACKGROUND AND PURPOSE: The effort to translate clinical findings across institutions employing different relative biological effectiveness (RBE) models of ion radiotherapy has rapidly grown in recent years. Nevertheless, even for a chosen RBE model, different implementations exist. These approaches might consider or disregard the dose-dependence of the RBE and the radial variation of the radiation quality around the beam axis. This study investigated the theoretical impact of disregarding these effects during the RBE calculations...
January 2024: Physics and Imaging in Radiation Oncology
https://read.qxmd.com/read/38537305/implementation-of-a-new-egsnrc-particle-source-class-for-computed-tomography-validation-and-uncertainty-quantification
#29
JOURNAL ARTICLE
Marie-Luise Kuhlmann, Stefan Pojtinger
Personalized dose monitoring and risk management are of increasing significance with the growing number of computer tomography (CT) examinations. These require high-quality Monte Carlo (MC) simulations that are of the utmost importance for the new developments in personalized CT dosimetry. 
This work aims to extend the MC framework EGSnrc source code with a new particle source. This, in turn, allows CT-scanner-specific dose and image calculations for any CT scanner. The novel method can be used with all modern EGSnrc user codes, particularly for the simulation of the effective dose based on DICOM images and the calculation of CT images...
March 27, 2024: Physics in Medicine and Biology
https://read.qxmd.com/read/38537301/-sapphire-establishment-of-s-mall-a-nimal-p-roton-and-ph-oton-i-mage-guided-r-adiation-e-xperiments
#30
JOURNAL ARTICLE
Moritz Schneider, Joshua Dietrich Schilz, Michael Schürer, Sebastian Gantz, Anne Dreyer, Gert Rothe, Falk Tillner, Elisabeth Bodenstein, Felix Horst, Elke Beyreuther
The in vivo evolution of radiotherapy necessitates innovative platforms for preclinical investigation, bridging the gap between bench research and clinical applications. Understanding the nuances of radiation response, specifically tailored to proton and photon therapies, is critical for optimizing treatment outcomes. Within this context, preclinical in vivo experimental setups incorporating image guidance for both photon and proton therapies are pivotal, enabling the translation of findings from small animal models to clinical settings...
March 27, 2024: Physics in Medicine and Biology
https://read.qxmd.com/read/38537256/radiation-levels-outside-a-patient-undergoing-177lu-psma-radioligand-therapy
#31
JOURNAL ARTICLE
Huan Li, Haikuan Liu, Weiyuan Zhang, Lin Xin, Zhiling Li, Weihai Zhuo
Understanding the spatial distribution of radiation levels outside of a patient undergoing 177Lu radioligand therapy is not only helpful for conducting correct tests for patient release, but also useful for estimation of its potential exposure to healthcare workers, caregivers, family members, and the general public. In this study, by mimicking the 177Lu-PSMA radioligand therapy for prostate cancers in an adult male, the spatial distribution of radiation levels outside of the phantom was simulated based on the Monte Carlo software of PHITS, and verified by a series of measurements...
March 27, 2024: Journal of Radiological Protection: Official Journal of the Society for Radiological Protection
https://read.qxmd.com/read/38534654/relationship-between-target-time-above-minimum-inhibitory-concentration-achievement-rate-of-meropenem-using-monte-carlo-simulation-and-in-hospital-survival-in-patients-with-pseudomonas-aeruginosa-bacteremia
#32
JOURNAL ARTICLE
Hajime Nakashima, Motoyasu Miyazaki, Tsuneo Kuwamura, Kazutaka Oda, Yumi Haga, Osamu Imakyure
Pseudomonas aeruginosa bacteremia is associated with a high mortality rate, and meropenem (MEPM) is commonly used to treat it. However, the relationship between the time above the minimum inhibitory concentration ( f T>MIC ) of MEPM and its therapeutic efficacy in P. aeruginosa bacteremia has not been explored. This study aimed to investigate this relationship by defining the target % f T>MIC of MEPM as 75%. The retrospective study spanned 14 years and included hospitalized patients treated with MEPM for P...
February 27, 2024: Antibiotics
https://read.qxmd.com/read/38531243/a-study-on-the-treatment-of-brain-tumors-with-bnct-using-several-moderators-with-different-thicknesses
#33
JOURNAL ARTICLE
Yinan Zhu, Zuokang Lin, Haiyan Yu, Xiaohan Yu
Boron neutron capture therapy (BNCT) is an effective binary radiation therapy that depends on nuclear capture reactions. In recent years, BNCT can be performed without a reactor owing to the development of accelerator-based neutron sources. A new BNCT irradiation facility is proposed, which is based on a 15 mA 2.5 MeV proton accelerator with a 100 μm thickness natural lithium target as a neutron converter. A great quantity of studies has shown that neutron beams with different spectra have unique therapeutic effects on tumors...
March 22, 2024: Applied Radiation and Isotopes
https://read.qxmd.com/read/38526252/improving-calculations-of-electron-eye-lens-operational-dose-coefficients-using-the-monte-carlo-codes-penelope-and-mcnp6-2
#34
JOURNAL ARTICLE
Jacques Dubeau, Jiansheng Sun, Salah Djeffal, Fawaz Ali
After considering epidemiological studies on the induction of cataracts in individuals exposed to radiation, the International Commission on Radiological Protection recommended, in 2012, a reduction in the annual eye-dose limit of occupationally exposed workers. This imposed higher performance demands on existing dosimetry systems and the development of new dosimetry technologies. The operational quantity to be measured is Hp(3), the personal dose equivalent at a depth of 3 mm in an ICRU 4-element tissue cylinder 20 cm in height and 20 cm in diameter...
May 1, 2024: Health Physics
https://read.qxmd.com/read/38518627/methodology-for-small-animals-targeted-irradiations-at-conventional-and-ultra-high-dose-rates-65%C3%A2-mev-proton-beam
#35
JOURNAL ARTICLE
Manon Evin, Charbel Koumeir, Arthur Bongrand, Gregory Delpon, Ferid Haddad, Quentin Mouchard, Vincent Potiron, Gaëlle Saade, Noël Servagent, Daphnée Villoing, Vincent Métivier, Sophie Chiavassa
As part of translational research projects, mice may be irradiated on radiobiology platforms such as the one at the ARRONAX cyclotron. Generally, these platforms do not feature an integrated imaging system. Moreover, in the context of ultra-high dose-rate radiotherapy (FLASH-RT), treatment planning should consider potential changes in the beam characteristics and internal movements in the animal. A patient-like set-up and methodology has been implemented to ensure target coverage during conformal irradiations of the brain, lungs and intestines...
March 20, 2024: Physica Medica: PM
https://read.qxmd.com/read/38518360/gate-monte-carlo-approach-to-heterogeneity-dose-distribution-in-small-fields-used-in-radiation-therapy
#36
JOURNAL ARTICLE
Zakaria Ait Elcadi, Mostafa El Moussaoui, Souha Aouadi, Renilmon Sukurmaran, Rabih Hammoud, Noora Al-Hammadi, Yassine Toufique, Othmane Bouhali
The Accurate dosage prediction in Radiation Therapy is challenging, prompting a need for precision beyond conventional clinical Treatment Planning Systems (TPS). Monte Carlo-based methods are sought for their superior accuracy.
The aim of this study is to compare dose distributions between the ACUROS algorithm and the GATE platform in various tissue densities and field sizes, focusing on smaller fields. This study was initiated with a homogeneous validation of the TrueBeam STX system, using measurements obtained from the Centre Hospitalier Interregional Edith Cavell (CHIREC) in Brussels...
March 22, 2024: Biomedical Physics & Engineering Express
https://read.qxmd.com/read/38509543/mr-compatible-detectors-assessment-for-a-0-35%C3%A2-t-mr-linac-commissioning
#37
JOURNAL ARTICLE
Michel Chea, Mathilde Croisé, Christelle Huet, Céline Bassinet, Mohamed-Amine Benadjaoud, Catherine Jenny
PURPOSE: To assess a large panel of MR compatible detectors on the full range of measurements required for a 0.35 T MR-linac commissioning by using a specific statistical method represented as a continuum of comparison with the Monte Carlo (MC) TPS calculations. This study also describes the commissioning tests and the secondary MC dose calculation validation. MATERIAL AND METHODS: Plans were created on the Viewray TPS to generate MC reference data. Absolute dose points, PDD, profiles and output factors were extracted and compared to measurements performed with ten different detectors: PTW 31010, 31021, 31022, Markus 34045 and Exradin A28 MR ionization chambers, SN Edge shielded diode, PTW 60019 microdiamond, PTW 60023 unshielded diode, EBT3 radiochromic films and LiF µcubes...
March 20, 2024: Radiation Oncology
https://read.qxmd.com/read/38507246/dosimetry-of-large-field-valencia-applicators-for-cobalt-60-based-brachytherapy
#38
JOURNAL ARTICLE
Gustavo H Píriz, Gabriel A Gonzalez-Sprinberg, Facundo Ballester, Javier Vijande
BACKGROUND: Non-melanoma skin cancer is one of the most common types of cancer and one of the main approaches is brachytherapy. For small lesions, the treatment of this cancer with brachytherapy can be done with two commercial applicators, one of these is the Large Field Valencia Applicators (LFVA). PURPOSE: The aim of this study is to test the capabilities of the LFVA to use clinically 60 Co sources instead of the 192 Ir ones. This study was designed for the same dwell positions and weights for both sources...
March 20, 2024: Medical Physics
https://read.qxmd.com/read/38501279/clonogenic-assay-and-computational-modeling-using-real-cell-images-to-study-physical-enhancement-and-cellular-sensitization-induced-by-metal-nanoparticles-under-mv-and-kv-x-ray-irradiation
#39
JOURNAL ARTICLE
Rodrigo Hernández Millares, Chaewon Bae, Seok-Jin Kim, Taewan Kim, So-Yeon Park, Kangwon Lee, Sung-Joon Ye
This study was initiated due to the physically unexplainable tumor controls resulting from metal nanoparticle (MNP) experiments even under MV X-ray irradiation. A more accurate explanation of the mechanism of radiosensitization induced by MNP is warranted, considering both its physical dose enhancement and biological sensitization, as related research is lacking. Thus, we aimed to examine the intricate dynamics involved in MNP-induced radiosensitization. We conducted specifically designed clonogenic assays for the A549 lung cancer cell line with MNP irradiated by 6 MV and 300 kVp X-rays...
March 19, 2024: Nanoscale
https://read.qxmd.com/read/38493501/first-monte-carlo-beam-model-for-ultra-high-dose-rate-radiotherapy-with-a-compact-electron-linac
#40
JOURNAL ARTICLE
Tianyuan Dai, Austin M Sloop, Mahbubur R Rahman, Jacob P Sunnerberg, Megan A Clark, Ralph Young, Sebastian Adamczyk, Philip Von Voigts-Rhetz, Chris Patane, Michael Turk, Lesley Jarvis, Brian W Pogue, David J Gladstone, Petr Bruza, Rongxiao Zhang
BACKGROUND: FLASH radiotherapy based on ultra-high dose rate (UHDR) is actively being studied by the radiotherapy community. Dedicated UHDR electron devices are currently a mainstay for FLASH studies. PURPOSE: To present the first Monte Carlo (MC) electron beam model for the UHDR capable Mobetron (FLASH-IQ) as a dose calculation and treatment planning platform for preclinical research and FLASH-radiotherapy (RT) clinical trials. METHODS: The initial beamline geometry of the Mobetron was provided by the manufacturer, with the first-principal implementation realized in the Geant4-based GAMOS MC toolkit...
March 17, 2024: Medical Physics
keyword
keyword
168642
2
3
Fetch more papers »
Fetching more papers... Fetching...
Remove bar
Read by QxMD icon Read
×

Save your favorite articles in one place with a free QxMD account.

×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"

We want to hear from doctors like you!

Take a second to answer a survey question.