keyword
https://read.qxmd.com/read/38630469/inter-individual-topographic-variation-of-choroidal-thickness-in-healthy-eyes-on-swept-source-optical-coherence-tomography
#1
JOURNAL ARTICLE
Zehua Jiang, Tian Lin, Aidi Lin, Xujia Liu, Xiaoting Mai, Jianwei Lin, Carol Y L Cheung, Haoyu Chen
PURPOSE: To investigate the topographic characters of inter-individual variations of the macular choroidal thickness (CT). METHODS: This was a retrospective study. Macular CT data for 900 0.2 × 0.2-mm grids from 410 healthy eyes were collected from swept-source optical coherence tomography. Following the analysis of factors associated with mean CT, the β-coefficients of the included associated factors in each grid were summarized for choroidal thickness changes analysis...
April 2, 2024: Translational Vision Science & Technology
https://read.qxmd.com/read/38625449/effects-of-cycloplegia-on-crystalline-lens-morphology-and-location-in-acute-acquired-concomitant-esotropia
#2
JOURNAL ARTICLE
Weibin Chen, Jiawen Liu, Wei Dai, Jie Hao, Jiayu Chen, Jing Fu
PURPOSE: The study aims to compare morphology and location of crystalline lens between acute acquired concomitant esotropia (AACE) patients and control subjects, both before and after cycloplegia. METHODS: This is a prospective and observational clinical study. Morphological and locational parameters of the crystalline lens in 53 AACE patients and 32 control subjects were assessed before and after cycloplegia using CASIA2 system, which represents the latest swept-source anterior segment optical coherence tomography...
April 16, 2024: Graefe's Archive for Clinical and Experimental Ophthalmology
https://read.qxmd.com/read/38623407/temporal-protrusion-of-the-optic-disc-implicated-in-central-visual-field-abnormalities-in-high-myopia-two-case-reports
#3
Takuhei Nomura, Takeshi Yoshida, Taiju Ito, Kyoko Ohno-Matsui
INTRODUCTION: Severe central visual field defects are frequently observed in highly myopic eyes. This report details 2 cases of central visual field defects in individuals with high myopia, characterized by an unusual temporal protrusion of the optic disc, a feature not previously documented. CASE PRESENTATION: Two patients, a 54-year-old man and a 65-year-old woman, were diagnosed with high myopia in their left eyes, displaying an outward protrusion of the optic disc toward the macula...
2024: Case Reports in Ophthalmology
https://read.qxmd.com/read/38615097/quantitative-evaluation-of-oct-angiography-images-in-healthy-and-glaucomatous-subjects-through-a-novel-approach-exploring-inter-image-variability
#4
JOURNAL ARTICLE
Paola Cassottana, Costanza Iester, Laura Bonzano, Carlo E Traverso, Michele Iester
PURPOSE: This study aims to investigate inter-image intra-observer variability of macular, and optic disc (ONH) microvasculature measurements of glaucomatous and normal subjects using Swept-Source Optical Coherence Tomography Angiography (OCT-A) (OCT Topcon ImageNet 6; DRI OCT Triton, Topcon Corporation, JAPAN) - based imaging data analysis and processing with a newly made quantitative approach. METHODS: A total of 20 glaucomatous and 20 healthy eyes underwent three OCT-A scanning of the ONH and macula...
April 13, 2024: Eye
https://read.qxmd.com/read/38613580/nayf-4-ho-3-yb-3-nagdf-4-core-shell-upconversion-nanoparticles-for-contrast-enhancement-in-bimodal-in-vitro-oct-imaging
#5
JOURNAL ARTICLE
Kumar Shwetabh, Abhishek Banerjee, Raju Poddar, Kaushal Kumar
Contrast enhancement is explored in optical coherence tomography images using core NaYF4 :Ho3+ /Yb3+ and core@shell NaYF4 :Ho3+ /Yb3+ @NaGdF4 nanoparticles. Under 980 nm excitation, core@shell nanoparticles exhibited 2.8 and 3.3 times enhancement at 541 nm and 646 nm emission wavelengths of Ho3+ ions compared to core nanoparticles. Photo-thermal conversion efficiencies were 32% and 20% for core and core@shell nanoparticles. In swept-source optical coherence tomography (SSOCT), core@shell nanoparticles have shown superior contrast, while in photo-thermal optical coherence tomography (PTOCT) core nanoparticles have excelled due to their higher photo-thermal conversion efficiency...
April 13, 2024: Mikrochimica Acta
https://read.qxmd.com/read/38611663/quantitative-microvascular-change-analysis-using-a-semi-automated-algorithm-in-macula-on-rhegmatogenous-retinal-detachment-assessed-by-swept-source-optical-coherence-tomography-angiography
#6
JOURNAL ARTICLE
Pablo Díaz-Aljaro, Xavier Valldeperas, Laura Broc-Iturralde, Nevena Romanic-Bubalo, Ignacio Díaz-Aljaro, Zhongdi Chu, Ruikang K Wang, Javier Zarranz-Ventura
PURPOSE: The purpose of this study was to objectively evaluate the longitudinal changes observed in the retinal capillaries in eyes with macula-on rhegmatogenous retinal detachment (RRD), assessed with optical coherence tomography angiography (OCTA), and to assess the role of these microvascular measures as potential biomarkers of postoperative visual outcomes. METHODS: This was a prospective, longitudinal study conducted on consecutive patients who underwent 25 G pars plana vitrectomy for primary RRD...
April 1, 2024: Diagnostics
https://read.qxmd.com/read/38610913/assessment-of-changes-in-cap-and-residual-stromal-thickness-values-during-a-6-month-observation-after-refractive-lenticule-extraction-small-incision-lenticule-extraction
#7
JOURNAL ARTICLE
Dominika Janiszewska-Bil, Barbara Czarnota-Nowakowska, Izabela Kuciel-Polczak, Dariusz Dobrowolski, Beniamin Oskar Grabarek, Anita Lyssek-Boroń, Edward Wylęgała, Joanna Wierzbowska
Background : In this study, the changes in corneal cap and residual stromal thickness (RST) values during a 180-day observation period after refractive lenticule extraction small incision lenticule extraction (ReLEx SMILE) were assessed. Methods: Fifty patients underwent ReLEx SMILE using the VisuMax 500 femtosecond laser, with corneal imaging conducted pre and post procedure via anterior segment optical coherence tomography (AS-OCT). Cap thickness in the center and 1.5 mm from the center in four meridians was measured at various intervals...
April 8, 2024: Journal of Clinical Medicine
https://read.qxmd.com/read/38607633/visualization-of-cataract-surgery-steps-with-4d-microscope-integrated-swept-source-optical-coherence-tomography-in-ex-vivo-porcine-eyes
#8
JOURNAL ARTICLE
Anja Britten, Philipp Matten, Jonas Nienhaus, Jennifer-Magdalena Masch, Katharina Dettelbacher, Hessam Roodaki, Nancy Hecker-Denschlag, Rainer A Leitgeb, Wolfgang Drexler, Andreas Pollreisz, Tilman Schmoll
PURPOSE: To investigate the visualization capabilities of high-speed swept-source optical coherence tomography (SS-OCT) in cataract surgery. METHODS: Cataract surgery was simulated in wet labs with ex vivo porcine eyes. Each phase of the surgery was visualized with a novel surgical microscope-integrated SS-OCT with a variable imaging speed of over 1 million A-scans per second. It was designed to provide four-dimensional (4D) live-volumetric videos, live B-scans, and volume capture scans...
April 2, 2024: Translational Vision Science & Technology
https://read.qxmd.com/read/38602030/atypical-phacolytic-glaucoma-diagnosed-by-biometry-and-anterior-segment-optical-coherence-tomography-oct-in-a-patient-with-cmv-anterior-uveitis
#9
JOURNAL ARTICLE
Efthymios Karmiris, Evangelia Papakonstantinou, Konstantinos Tsiripidis, Panagiotis Stavrakas, Ioannis Giannakis, Evangelia Chalkiadaki
PURPOSE: To report a case of phacolytic glaucoma with atypical presentation in a patient which was diagnosed with biometry swept source optical coherence tomography (SS-OCT) and anterior segment spectral domain OCT (SD-OCT). METHODS: A 56-year-old male with a history of cytomegalovirus (CMV) chronic anterior uveitis in the right eye presented with a white cataract, minimal anterior chamber reaction and intraocular pressure (IOP) of 56 mmHg. Visual acuity was light perception...
April 11, 2024: European Journal of Ophthalmology
https://read.qxmd.com/read/38594403/evaluation-of-changes-of-anterior-segment-parameters-in-patients-with-pseudoexfoliation-syndrome-after-cataract-surgery-using-anterior-segment-optical-coherence-tomography
#10
JOURNAL ARTICLE
Aleksandra Wlaź, Agnieszka Kustra, Tin Aung, Tomasz Żarnowski
The aim of the study was to compare the anterior segment parameters after cataract surgery in pseudoexfoliation syndrome (PEX) and control eyes. We conducted a prospective comparative study of 36 eyes (PEX group), 16 eyes (PEXG group) and 46 eyes (control group) of 98 patients after phacoemulsification with intraocular lens implantation. Before surgery, 1 week, 1 month and 3 months postoperatively, anterior chamber parameters were evaluated by swept source anterior segment optical coherence tomography (AS-OCT)...
April 9, 2024: Scientific Reports
https://read.qxmd.com/read/38594062/diagnostic-criteria-of-anterior-segment-swept-source-optical-coherence-tomography-to-detect-gonioscopic-angle-closure
#11
JOURNAL ARTICLE
Philip Yawen Guo, Xiulan Zhang, Fei Li, Chen Lin, Anwell Nguyen, Rei Sakata, Risa Higashita, Keiichiro Okamoto, Marco Yu, Makoto Aihara, Tin Aung, Shan Lin, Christopher Kai-Shun Leung
AIMS: To compare the diagnostic performance of 360° anterior segment optical coherence tomography assessment by applying normative percentile cut-offs versus iris trabecular contact (ITC) for detecting gonioscopic angle closure. METHODS: In this multicentre study, 394 healthy individuals were included in the normative dataset to derive the age-specific and angle location-specific normative percentiles of angle open distance (AOD500) and trabecular iris space area (TISA500) which were measured every 10° for 360°...
April 9, 2024: British Journal of Ophthalmology
https://read.qxmd.com/read/38589233/peripapillary-atrophy-area-predicts-the-decrease-of-macular-choroidal-thickness-in-young-adults-during-myopia-progression
#12
JOURNAL ARTICLE
Menghan Li, Ya Shi, Qiuying Chen, Guangyi Hu, Jiamin Xie, Luyao Ye, Ying Fan, Jianfeng Zhu, Jiangnan He, Xun Xu
OBJECTIVE: This study aimed to investigate the influence of peripapillary atrophy (PPA) area and axial elongation on the longitudinal changes in macular choroidal thickness (ChT) in young individuals with myopia. METHODS AND ANALYSIS: In this longitudinal investigation, 431 eyes-342 categorised as non-high myopia (non-HM) and 89 as HM-were examined for 2 years. Participants were examined with swept-source optical coherence tomography. The macular ChT, PPA area and axial length (AL) were measured at baseline and follow-up visits...
April 8, 2024: BMJ Open Ophthalmology
https://read.qxmd.com/read/38586194/reduced-contrast-sensitivity-function-is-correlated-with-changes-to-cone-photoreceptors-in-simple-high-myopia
#13
JOURNAL ARTICLE
Jiefang Wang, Xinting Liu, Jing Huang, Ruoyun Deng, Sijun Zhao, Yulei Chen, Zhaohe Chen, Yanli Wang, Yu Rong, Qian Liu, Jia Qu, Xinjie Mao
PURPOSE: To investigate the contrast sensitivity function (CSF) changes in simple high myopia (SHM) and evaluate the correlations between these changes with the early changes in the retinal microstructure. METHODS: This prospective study comprised 81 subjects, 20 with emmetropia (EM), 26 with low myopia and moderate myopia (LM/MM), and 35 with SHM. The area under the log CSF curve (AULCSF) and the cut-off spatial frequency (Cut-off SF) were employed as measures of CSF...
2024: Frontiers in Neuroscience
https://read.qxmd.com/read/38581607/dynamic-changes-of-capsular-intraocular-lens-adhesion-in-plate-haptic-hydrophilic-and-loop-haptic-hydrophobic-eyes
#14
JOURNAL ARTICLE
Yinying Zhao, Zhewen Zhang, Fuman Yang, Pingjun Chang, Dandan Wang, Feng Huang, Yune Zhao
INTRODUCTION: The aim of this work is to investigate the dynamic changes of capsular-intraocular lens (IOL) adhesion in plate-haptic hydrophilic and loop-haptic hydrophobic eyes. METHODS: Cataract eyes that met the inclusion criteria were randomly assigned to receive implantation of a plate-haptic hydrophilic or loop-haptic IOL. The anterior capsular adhesion, posterior capsular adhesion, and the configurations of the capsular bend were evaluated using swept-source optical coherence tomography at 1 day, 1 week, 1 month, and 3 months postoperatively...
April 6, 2024: Ophthalmology and Therapy
https://read.qxmd.com/read/38581606/accuracy-of-toric-intraocular-lens-calculators-with-predicted-and-measured-posterior-corneal-astigmatism-across-different-types-of-astigmatism
#15
JOURNAL ARTICLE
Soonwon Yang, Jaehyun Park, Woong Joo Whang, Yong-Soo Byun, Hyun Seung Kim, So-Hyang Chung
INTRODUCTION: This study is a retrospective case series to compare the accuracy of the Barrett toric calculator using predicted posterior corneal astigmatism (PCA) and PCA measurements using swept-source optical coherence tomography (SS-OCT) and a Scheimpflug camera. This evaluation was conducted across different types of anterior and posterior astigmatism. METHODS: A total of 146 eyes from 146 patients implanted with toric intraocular lenses were included. Mean absolute prediction error, standard deviation of prediction error, and the percentage of eyes with prediction errors within ±0...
April 6, 2024: Ophthalmology and Therapy
https://read.qxmd.com/read/38575630/delineation-of-three-dimensional-tumor-margins-based-on-normalized-absolute-difference-mapping-via-volumetric-optical-coherence-tomography
#16
JOURNAL ARTICLE
Jae-Sung Park, Taeil Yoon, Soon A Park, Byeong Ha Lee, Sin-Soo Jeun, Tae Joong Eom
The extent of surgical resection is an important prognostic factor in the treatment of patients with glioblastoma. Optical coherence tomography (OCT) imaging is one of the adjunctive methods available to achieve the maximal surgical resection. In this study, the tumor margins were visualized with the OCT image obtained from a murine glioma model. A commercialized human glioblastoma cell line (U-87) was employed to develop the orthotopic murine glioma model. A swept-source OCT (SS-OCT) system of 1300 nm was used for three-dimensional imaging...
April 5, 2024: Scientific Reports
https://read.qxmd.com/read/38571248/visualizing-features-with-wide-field-volumetric-oct-angiography
#17
JOURNAL ARTICLE
Tristan T Hormel, Guangru B Liang, Xiang Wei, Yukun Guo, Min Gao, Jie Wang, David Huang, Steven T Bailey, Thomas S Hwang, Yali Jia
Optical coherence tomography (OCT) and its extension OCT angiography (OCTA) have become essential clinical imaging modalities due to their ability to provide depth-resolved angiographic and tissue structural information non-invasively and at high resolution. Within a field of view, the anatomic detail available is sufficient to identify several structural and vascular pathologies that are clinically relevant for multiple prevalent blinding diseases, including age-related macular degeneration (AMD), diabetic retinopathy (DR), and vein occlusions...
March 11, 2024: Optics Express
https://read.qxmd.com/read/38571173/full-range-depth-encoded-swept-source-polarization-sensitive-optical-coherence-tomography
#18
JOURNAL ARTICLE
Tong Wu, Hengyu Shi, Xinkang Zhou, Youwen Liu, Ling Wang, Yaoyao Shi, Jiming Wang, Yuangang Lu, Xiaorong Gu, Chongjun He
To realize the high sensitivity polarization sensitive optical coherence tomography (PS-OCT) imaging, a fiber-based full-range depth-encoded swept source PS-OCT (SS-PS-OCT) method is proposed. The two OCT images corresponding to the orthogonal polarized input light are located on the high sensitivity imaging region of the opposite sides relative to the zero optical path difference position. The full-range OCT images can be obtained by implementing the spatial phase modulation in the reference arm. The detection sensitivity of the system was measured experimentally to be 67 dB when the imaging depth approaching to 2 mm...
March 11, 2024: Optics Express
https://read.qxmd.com/read/38569172/en-face-depth-resolved-octa-monitoring-of-macular-outer-retinal-deposits-in-a-case-of-multifocal-choroiditis-mimicking-syphilitic-uveitis
#19
JOURNAL ARTICLE
Christian Akotoye, Sandra Hoyek, Itika Garg, Nakul Singh, John B Miller, Lucia Sobrin, Nimesh A Patel
PURPOSE: Multifocal choroiditis (MFC) is a rare inflammatory condition characterized by retinal and choroidal lesions that may present similarly to ocular pathology of various etiologies. Here we present a case of MFC mimicking syphilitic uveitis with unique en face optical coherence tomography angiography (OCTA) imaging characteristics. METHODS: Case report. RESULTS: A 61-year-old woman presented with blurry vision, floaters and multiple whitish subretinal deposits on en face swept-source OCTA in the left eye...
March 27, 2024: Retinal Cases & Brief Reports
https://read.qxmd.com/read/38568554/algorithm-and-software-for-field-distortion-correction-in-a-commercial-sd-oct-for-corneal-curvature-assessment
#20
JOURNAL ARTICLE
Maron Dolling, Lara Buhl, Reginald Birngruber, Gereon Hüttmann, Hinnerk Schulz-Hildebrandt
Accurate assessment of corneal curvatures using frequency domain optical coherence tomography (OCT) with galvanometer scanners remains challenging due to the well-known scan field distortion. This paper presents an algorithm and software for correcting the distortion using only two simple measurements in which a readily available standard sphere is positioned in different depths in front of the OCT scanner. This offers a highly accessible and easily reproducible method for the field distortion correction (FDC)...
April 1, 2024: Applied Optics
keyword
keyword
167248
1
2
Fetch more papers »
Fetching more papers... Fetching...
Remove bar
Read by QxMD icon Read
×

Save your favorite articles in one place with a free QxMD account.

×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"

We want to hear from doctors like you!

Take a second to answer a survey question.