keyword
https://read.qxmd.com/read/38515618/tension-band-high-strength-suture-combined-with-absorbable-cannulated-screws-for-treating-transverse-patellar-fractures-finite-element-analysis-and-clinical-study
#21
JOURNAL ARTICLE
Feifan Xiang, Yukun Xiao, Dige Li, Wenzhe Ma, Yue Chen, Yunkang Yang
Objective: Few reports exist on the treatment of transverse patellar fractures (TPFs) using absorbable cannulated screws and high-strength sutures, and most screws and sutures lack good biomechanics and clinical trials. Therefore, this study aimed to demonstrate the biomechanical stability and clinical efficacy of tension-band high-strength sutures combined with absorbable cannulated screws (TBSAS) in treating TPFs (AO/OTA 34 C1). Methods: Finite element models of five internal fixation schemes were established: tension-band wire with K-wire (TBW), TBW with cerclage wire (TBWC), TBW with headless pressure screws (TBWHS), TBW with full-thread screws (TBWFS), and TBSAS...
2024: Frontiers in Bioengineering and Biotechnology
https://read.qxmd.com/read/38505344/does-early-stable-fixation-reduce-complications-in-paediatric-femoral-neck-fractures
#22
JOURNAL ARTICLE
Asad Khan, Yasir S Siddiqui, Mohd Baqar Abbas, Mazhar Abbas, Julfiqar Mohd, Mohd Hadi Aziz
The primary objective of this study was to juxtapose the union rate and incidence of complications in paediatric patients presenting early (≤ 7 days) following injury with children presenting later (> 7 days) with femoral neck fractures. This critical appraisal evaluated 15 patients according to their timing of presentation and surgery from the initial day of injury (Group A: operated ≤ 7 days or Group B: > 7 days of injury). Patients with traumatic femoral neck fractures with Delbet 1 to 4 subtypes who were skeletally immature (age ≤ 16 years) were included in the study...
2024: International Journal of Burns and Trauma
https://read.qxmd.com/read/38503306/biomechanical-stability-of-femoral-neck-system-for-pauwels-type-iii-femoral-neck-fractures-based-on-different-reduction-quality
#23
JOURNAL ARTICLE
Daoqiang Huang, Xiaoping Wang, Bingze Chen, Zhiqiang Hu, Weili Feng
To further investigate the biomechanics of a femoral neck system (FNS) for Pauwels type III femoral fractures based on three different reductions.We constructed three different reduction (anatomical reduction, negative buttress reduction, and positive buttress reduction) models of Pauwels type III femoral neck fractures. Then, three cannulated screws (3CS), dynamic hip screws (DHS), dynamic hip screws combined with an anti-rotation screw (DHS + ARS), one-hole femoral neck system (1HFNS), and two-hole femoral neck system (2HFNS) were assembled with the reduction models, respectively, to simulate the internal fixation surgical procedure...
March 19, 2024: Zeitschrift Für Orthopädie und Unfallchirurgie
https://read.qxmd.com/read/38500422/-correlation-analysis-between-combined-deflection-angle-and-osteonecrosis-of-femoral-head-after-femoral-neck-fracture
#24
JOURNAL ARTICLE
Congcong Luo, Yiping Dong, Qiang Yuan, Ning Zhang, Ying Zhang
OBJECTIVE: To evaluate the correlation between pelvic incidence (PI) angle, hip deflection angle (HDA), combined deflection angle (CDA) and osteonecrosis of the femoral head (ONFH) after femoral neck fracture, in order to explore early predictive indicators for ONFH occurrence after femoral neck fracture. METHODS: A study was conducted on patients with femoral neck fractures who underwent cannulated screw internal fixation between December 2018 and December 2020...
March 15, 2024: Chinese Journal of Reparative and Reconstructive Surgery
https://read.qxmd.com/read/38493931/establishing-finite-element-model-credibility-of-a-pedicle-screw-system-under-compression-bending-an-end-to-end-example-of-the-asme-v-v-40-standard
#25
JOURNAL ARTICLE
Srinidhi Nagaraja, Galyna Loughran, Andrew P Baumann, Kumar Kartikeya, Marc Horner
Computational modeling and simulation (CM&S) is a key tool in medical device design, development, and regulatory approval. For example, finite element analysis (FEA) is widely used to understand the mechanical integrity and durability of orthopaedic implants. The ASME V&V 40 standard and supporting FDA guidance provide a framework for establishing model credibility, enabling deeper reliance on CM&S throughout the total product lifecycle. Examples of how to apply the principles outlined in the ASME V&V 40 standard are important to facilitating greater adoption by the medical device community...
March 15, 2024: Methods: a Companion to Methods in Enzymology
https://read.qxmd.com/read/38475888/increasing-the-angle-between-caudal-screw-and-the-transverse-plane-may-aggravate-the-risk-of-femoral-head-necrosis-by-deteriorating-the-fixation-stability-in-patients-with-femoral-neck-fracture
#26
JOURNAL ARTICLE
Jian Zhang, Shengyu Wan, Xiaozhong Luo, Caidong Zhang, Chao Wu, Lipeng He, Jingchi Li
Necrosis of the femoral head is the main complication in femoral neck fracture patients with triangle cannulated screw fixation. Instant postoperative fixation instability is a main reason for the higher risk of femoral head necrosis. Biomechanical studies have shown that cross screw fixation can effectively optimize fixation stability in patients with proximal humerus fractures and pedicle screw fixation, but whether this method can also effectively optimize the fixation stability of femoral neck fractures and reduce the corresponding risk of femoral head necrosis has yet to be identified...
March 12, 2024: European Journal of Medical Research
https://read.qxmd.com/read/38449685/percutaneous-posterior-to-anterior-screw-fixation-through-achilles-tendon-for-posterior-malleolus-fractures-technique-description-and-case-series
#27
JOURNAL ARTICLE
Apostolos Dimitroulias, Danielle Putur, Yelena Bogdan, Milan K Sen
Posterior malleolus fractures (PMFs) (OTA 43B1.1) are frequently seen in combination with fractures of the fibula, medial malleolus, and distal tibia; they can rarely be seen in isolation. PMFs affect the alignment of the ankle mortise and the stability of syndesmosis. Techniques described for fixation of PMFs include open reduction internal fixation through a posterolateral or posteromedial approach or anterior-to-posterior screw fixation. For selected minimally displaced or nondisplaced fractures of the posterior malleolus, we developed a percutaneous technique through the Achilles tendon for the insertion of a posterior-to-anterior cannulated screw...
March 2024: OTA international: the open access journal of orthopaedic trauma
https://read.qxmd.com/read/38447563/-arthroscopic-subtalar-distraction-arthrodesis-in-post-traumatic-indications
#28
JOURNAL ARTICLE
V Rak, J Šrámek, D Ira, M Krtička
PURPOSE OF THE STUDY: This manuscript aims to present the method of arthroscopic assisted subtalar arthrodesis and to evaluate the benefi ts of this surgery on our study population. MATERIAL AND METHODS: In the period from 9/2007 to 1/2020, a total of 33 subtalar arthrodesis were performed in 31 patients aged 19-66 years (mean 48 years, median 50 years). The indication for arthrodesis was subtalar arthritis causing pain and gait disorders, or hindfoot deformities (most commonly after a calcaneus bone fracture)...
2024: Acta Chirurgiae Orthopaedicae et Traumatologiae Cechoslovaca
https://read.qxmd.com/read/38432861/efficacy-comparison-between-iliosacral-screw-fixation-of-the-posterior-pelvic-ring-fracture-with-the-assistance-of-modified-percutaneous-three-dimensional-printing-guide-template-and-conventional-fluoroscopy
#29
JOURNAL ARTICLE
Feng Liu, Qing Lei, Lihong Cai, Minghui Jiang, Hongqi Yang, Kang Wang, Zhou Ding, Wenqian Liu
OBJECTIVES: The effect of three-dimensional (3D) printed bone-attached guide plate assisted cannulated screw fixation of pelvic fracture is reliable, but extensive soft tissue dissection is still required when installing the guide plate. This study aims to compare the efficacy of posterior pelvic ring fracture fixation with iliosacral screw insertion between the assistance of modified percutaneous patient specific 3D printed guide template and conventional fluoroscopy. METHODS: From May, 2019 and September 2021, 28 patients sustained posterior pelvic ring fractures were randomized into 2 groups: A guide template group, in which the iliosacral screw was inserted for fixation of the posterior pelvic ring fracture with the assistance of modified percutaneous patient specific 3D printed guide template, and a fluoroscopy group, in which the iliosacral screw was inserted under the guidance of conventional fluoroscopy...
November 28, 2023: Zhong Nan da Xue Xue Bao. Yi Xue Ban, Journal of Central South University. Medical Sciences
https://read.qxmd.com/read/38428485/treatment-of-old-femoral-neck-fractures-in-young-adults-with-a-medial-buttress-plate-combined-with-three-cannulated-screws-and-iliac-autograft-surgical-technique-and-preliminary-results
#30
JOURNAL ARTICLE
Guanglei Zhao, Wenjun Chen, Jianguo Wu, Tiancong Ma, Siqun Wang, Yibing Wei, Jun Xia, Gangyong Huang
OBJECTIVES: Whether the application of MBP plus cannulated screws works for old femoral neck fractures(OFNF) is unknown.The purpose of this study is to present a case series of OFNF in young adults using calcar buttress plate and three cannulated screws with autologous iliac bone grafts. METHODS: We conducted a retrospective study of eleven young patients (6 males and 5 females) with femoral neck fractures who were treated with open reduction and internal fixation at a single center between 2013 and 2021...
February 28, 2024: Orthopaedics & Traumatology, Surgery & Research: OTSR
https://read.qxmd.com/read/38425543/effect-of-extrusion-on-energy-and-nutrient-digestibility-of-lentil-based-diets-containing-either-supplemental-plant-or-animal-protein-fed-to-growing-pigs
#31
JOURNAL ARTICLE
Joaquin Sanchez-Zannatta, Li Fang Wang, Eduardo Beltranena, Ruurd T Zijlstra
Non-food grade and excess lentil grain production may be included in swine feeds to provide starch and protein and reduce feed cost. Extrusion processing may increase energy and nutrient digestibility of lentil-based diets containing either supplemental plant or animal protein sources. Therefore, the apparent ileal digestibility ( AID ) of crude protein ( CP ) and amino acids ( AA ), apparent total tract digestibility ( ATTD ) of gross energy ( GE ), and digestible energy ( DE ) value of lentil-based diets were assessed in growing pigs...
2024: Translational Animal Science
https://read.qxmd.com/read/38425062/-comparison-of-the-efficacy-of-tirobot-orthopaedic-robot-assisted-f-screw-technique-and-inverted-triangle-parallel-nail-internal-fixation-in-the-treatment-of-unstable-femoral-neck-fractures
#32
JOURNAL ARTICLE
Xing-Long Zhao, Jian-Jun Shen, Kang-Hu Feng, Zhi-Wei Chen, Yuan-Long Si, Xuan Zhang, Guan-de Wang, Xiang Hai
OBJECTIVE: To compare the effectiveness of TiRobot assisted F screw technique and inverted triangle parallel nail internal fixation in the treatment of unstable femoral neck fractures. METHODS: A retrospective analysis was conducted on 72 patients with unstable femoral neck fractures who were treated with percutaneous cannulated screw fixation assisted with TiRobot Orthopaedic robot from December 2019 to April 2021. Among them, 37 patients were treated with F screw internal fixation, including 16 males and 21 females, aged 47 to 64 years old with an average of (53...
February 25, 2024: Zhongguo Gu Shang, China Journal of Orthopaedics and Traumatology
https://read.qxmd.com/read/38425060/-orthopaedic-robot-assisted-closed-reduction-and-cannulated-screw-internal-fixation-for-the-treatment-of-femoral-neck-fractures
#33
JOURNAL ARTICLE
Shou-Hai Jiang, Chuan-Kai Zhang, Fang-Teng Jia, Qiang Chen, Meng Xu, Pei-Lin Yang, Yu-Shuai Zhang
OBJECTIVE: To investigate the preliminary clinical effect of closed reduction and cannulated nail internal fixation for femoral neck fracture assisted by robot navigation and positioning system. METHODS: From July 2019 to January 2020, 16 cases of femoral neck fracture (navigation group) were treated with closed reduction and internal fixation guided by robot system, including 7 males and 9 females, aged 25 to 72 years old with an average of (53...
February 25, 2024: Zhongguo Gu Shang, China Journal of Orthopaedics and Traumatology
https://read.qxmd.com/read/38421148/femoral-neck-system-as-a-safe-alternative-to-cannulated-compression-screw-and-dynamic-hip-screw-in-femoral-neck-fractures-an-early-comparative-study
#34
JOURNAL ARTICLE
Zhe Zheng Clyde Lim, Cheryl Marise Peilin Tan, Rex Premchand Antony Xavier, Michael Gui Jie Yam, Ivan Tjun Huat Chua
INTRODUCTION: The femoral neck system (FNS) is a safe alternative to cannulated compression screw (CCS) and dynamic hip screw (DHS) in femoral neck fractures. METHODS: A dual-centre retrospective cohort study was performed on femoral neck fractures (AO type 31-B) treated with closed reduction and internal fixation using FNS, DHS or CCS between April 2016 and April 2020. Exclusion criteria were as follows: patients aged below 16 years; chronic fractures beyond 7 days; pathological fractures; fracture extension to the intertrochanteric region or ipsilateral neck and shaft fractures; and open fractures...
January 8, 2024: Singapore Medical Journal
https://read.qxmd.com/read/38420247/peri-implant-fracture-following-prior-fixation-of-femoral-neck-fracture-using-the-femoral-neck-system-a-case-report
#35
David Gregory, Roy Small, Michael Milshteyn, Christopher Vitale
INTRODUCTION: Peri-implant fractures (PIF) reported after cannulated screw and dynamic hip screw fixation historically occur distal to the implant within the subtrochanteric region secondary to the development of a stress riser. Newer implant designs for femoral neck fractures have attempted to combine the benefits of minimally invasive techniques without forgoing rigid angular stability but bring new potential complications. CASE REPORT: We present a case of an intertrochanteric PIF in the setting of a non-displaced femoral neck fracture treated with the DePuy Synthes Femoral Neck System (FNS)...
February 2024: Journal of Orthopaedic Case Reports
https://read.qxmd.com/read/38420242/trifocal-injury-of-the-patellar-tendon-an-exceedingly-rare-case-report
#36
Sandeep Deore, Sachin Kale, Ajit Chalak, Rahul Ghodke, Nrupam Mehta, Ravi Modi
INTRODUCTION: Distal pole of patella avulsion fracture with tibial tuberosity avulsion has been frequently reported as a bifocal patellar tendon injury. However, an osteochondral lateral patella facet fracture with a longitudinal split in the patella tendon in addition to these avulsion fractures has never been documented previously. Hence, we now report this trifocal patellar tendon injury. CASE REPORT: An adolescent with a trifocal patella tendon injury underwent a fixation with a combination of transosseous pull- through sutures, suture tape, and knotless anchor...
February 2024: Journal of Orthopaedic Case Reports
https://read.qxmd.com/read/38420227/patella-fracture-fixation-technique-with-suture-anchors
#37
Madhav Kukreja, Vivek Dubey, Daoud Makki
INTRODUCTION: Patella fracture can occur due to direct injury to the knee or indirect eccentric contraction of the quadriceps tendon. These injuries can present in different configurations which require acceptable reduction and good fixation. Patients are at risk of not only losing their knee extensor mechanism but also having a defective patellofemoral articulation. Hence, the main aim in treating such fractures is to restore the knee extensor mechanism. Surgical options for treating patella fracture include tension band wiring, wiring through cannulated screws, fixation with plate, and suture anchor (SA) fixation...
February 2024: Journal of Orthopaedic Case Reports
https://read.qxmd.com/read/38418739/two-step-osteotomy-discectomy-through-cannulated-screw-tocs-technique-for-en-bloc-resection-of-spine-tumor-surgical-technique-and-preliminary-results
#38
JOURNAL ARTICLE
Ran Wei, Kunkun Sun, Wei Guo, Tao Ji, Yiyang Yu, Zhiye Du, Yi Yang, Xiaodong Tang
PURPOSE: We have developed a novel technique for osteotomy/discectomy during en bloc resection of spine tumors named two-step osteotomy/discectomy through cannulated screw (TOCS). This study aims at describing the procedure of TOCS technique and assessing its efficiency and safety. METHODS: We retrospectively reviewed fourteen patients who underwent en bloc resection for spine tumors using TOCS technique in our center between August 2018 and September 2022. The technique was based on a specially designed "slotted" cannulated screw which was a cannulated screw with a longitudinal slot to provide the accessibility of T-saw...
February 28, 2024: European Spine Journal
https://read.qxmd.com/read/38389308/a-novel-technique-of-medial-displacement-calcaneal-osteotomy-using-the-intramedullary-fixation-of-a-conventional-low-profile-locking-wedge-plate
#39
JOURNAL ARTICLE
Jun Young Choi, Oh Jun Yu, Jin Soo Suh
BACKGROUND: Postoperative heel pain arising from prominent screw heads is a common complication following medial displacement calcaneal osteotomy (MDCO). This study aims to present the clinicoradiographic outcomes of a novel MDCO technique, wherein intramedullary fixation of a conventional low-profile locking wedge plate is employed. METHODS: A retrospective analysis, involving a comparison of clinical and radiographic parameters among consecutive patients who underwent MDCO was conducted...
February 22, 2024: Foot & Ankle International
https://read.qxmd.com/read/38389204/biomechanical-research-of-three-parallel-cannulated-compression-screws-in-oblique-triangle-configuration-for-fixation-of-femoral-neck-unstable-fractures
#40
JOURNAL ARTICLE
Ru-Yi Zhang, Wu-Peng Zhang, Guang-Min Yang, Dao-Feng Wang, Peng Su, Yi Zhang, Shao-Bo Nie, Jia Li, Zhe Zhao, Jian-Tao Li, Li-Cheng Zhang, Pei-Fu Tang
OBJECTIVE: Surgical treatment with internal fixation, specifically percutaneous fixation with three cannulated compression screws (CCSs), is the preferred choice for young and middle-aged patients. The mechanical advantage of the optimal spatial configuration with three screws provides maximum dispersion and cortical support. We suspect that the spatial proportion of the oblique triangle configuration (OTC) in the cross-section of the femoral neck isthmus (FNI) may significantly improve shear and fatigue resistance of the fixed structure, thereby stabilizing the internal fixation system in femoral neck fracture (FNF)...
February 22, 2024: Orthopaedic Surgery
keyword
keyword
161698
2
3
Fetch more papers »
Fetching more papers... Fetching...
Remove bar
Read by QxMD icon Read
×

Save your favorite articles in one place with a free QxMD account.

×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"

We want to hear from doctors like you!

Take a second to answer a survey question.