Prosthetic heart valve size and diameter

https://read.qxmd.com/read/22610164/manouguian-double-valve-replacement-in-a-6-year-old-girl
#21
JOURNAL ARTICLE
Tadahisa Sugiura, Takeshi Hiramatsu, Yusuke Iwata, Toru Okamura, Takeshi Konuma, Hiromi Kurosawa
A 6-year-old girl with a diagnosis of aortic regurgitation with stenosis and mitral regurgitation because of short chordae was referred to us for surgery. Echocardiography revealed that the aortic and the mitral annular diameters were 16 and 23 mm, respectively. The Ross procedure and mitral valvuloplasty were scheduled. During the procedure, we were concerned that aggressive mitral valvuloplasty might result in mitral stenosis. We therefore converted the procedure to double-valve replacement using the Manouguian technique because it was necessary to enlarge both the aortic and mitral annuli...
November 2012: General Thoracic and Cardiovascular Surgery
https://read.qxmd.com/read/22511810/prosthesis-annulus-discongruence-assessed-by-three-dimensional-transoesophageal-echocardiography-a-predictor-of-significant-paravalvular-aortic-regurgitation-after-transcatheter-aortic-valve-implantation
#22
JOURNAL ARTICLE
Ninel Santos, José Alberto de Agustín, Carlos Almería, Alejandra Gonçalves, Pedro Marcos-Alberca, Covadonga Fernández-Golfín, Eulogio García, Rosana Hernández-Antolín, Leopoldo Pérez de Isla, Carlos Macaya, José Zamorano
AIMS: Paravalvular aortic regurgitation (AR) is common after transcatheter aortic valve implantation (TAVI). This study aimed to assess the prosthesis/aortic annulus discongruence by three-dimensional (3D) transoesophageal (TOE) planimetry of aortic annulus and its impact on the occurrence of significant AR after TAVI. METHODS AND RESULTS: We included 33 patients who underwent TAVI with a balloon expandable device for severe aortic stenosis. To appraise the prosthesis/annulus discongruence, we defined a 'mismatch index' expressed as: annulus area - prosthesis area...
November 2012: European Heart Journal Cardiovascular Imaging
https://read.qxmd.com/read/22306570/-the-effects-of-implanted-valve-sizes-on-ventricular-hypertrophy-in-aortic-stenosis
#23
JOURNAL ARTICLE
Hikmet Selçuk Gedik, Kemal Korkmaz, Gökhan Lafçı, Adnan Yalçınkaya, Kerim Çağlı
OBJECTIVE: We aimed to study the effects of the valve sizes according to body surface area on aortic gradient and ventricular hypertrophy in the cases of aortic valve replacement due to isolated aortic stenosis. METHODS: Between January 2006 and April 2007, patients (12 men, 15 women; totally 27) followed up prospectively with echocardiography fourth and sixth month postoperatively. The patients were divided into two groups according to the prosthetic aortic valve diameters (19-21 mm vs 23-25 mm)...
March 2012: Anatolian Journal of Cardiology: AKD
https://read.qxmd.com/read/22293620/prevail-transapical-multicentre-trial-of-transcatheter-aortic-valve-implantation-using-the-newly-designed-bioprosthesis-sapien-xt-and-delivery-system-ascendra-ii
#24
MULTICENTER STUDY
Thomas Walther, Matthias Thielmann, Joerg Kempfert, Holger Schroefel, Gerhard Wimmer-Greinecker, Hendrik Treede, Thorsten Wahlers, Olaf Wendler
OBJECTIVES: Transapical (TA) aortic valve implantation (AVI) has evolved as an alternative procedure for high-risk patients. We evaluated the second-generation SAPIEN XT™ prosthesis in a prospective multicentre clinical trial. METHODS: A total of 150 patients (age: 81.6 ± 5.8 years; 40.7% female) were included. Prosthetic valves (diameter: 23 mm (n = 36), 26 mm (n = 57) and 29 mm (n = 57)) were implanted. The ASCENDRA-II™ modified delivery system was used in the smaller sizes...
August 2012: European Journal of Cardio-thoracic Surgery
https://read.qxmd.com/read/21999863/validation-and-characterization-of-transcatheter-aortic-valve-effective-orifice-area-measured-by-doppler-echocardiography
#25
COMPARATIVE STUDY
Marie-Annick Clavel, Josep Rodés-Cabau, Éric Dumont, Rodrigo Bagur, Sébastien Bergeron, Robert De Larochellière, Daniel Doyle, Eric Larose, Jean G Dumesnil, Philippe Pibarot
OBJECTIVES: The objectives were to compare different Doppler echocardiographic methods for the measurement of prosthetic valve effective orifice area (EOA) following transcatheter aortic valve implantation (TAVI) and to determine the factors influencing the EOA of transcatheter balloon expandable valves. BACKGROUND: Previous studies have used different methods for the measurement of the valve EOA following TAVI. Factors influencing the EOA of transcatheter valves are unknown...
October 2011: JACC. Cardiovascular Imaging
https://read.qxmd.com/read/21953731/aortic-valve-annulus-diameter-in-chinese-patients-with-severe-calcific-aortic-valve-stenosis-implications-for-transcatheter-aortic-valve-implantation
#26
COMPARATIVE STUDY
Wenzhi Pan, Daxin Zhou, Cuizhen Pan, Junbo Ge
OBJECTIVES: The objective of the study was to describe the distribution and determine the predictors of aortic valve annulus diameter (AVAD) in Chinese patients with severe calcific aortic valve stenosis (CAS). BACKGROUND: AVAD in Chinese patients with CAS has not been reported. Predictors of AVAD in patients with CAS are unclear. METHODS: One hundred elderly patients (≥60 years) with severe CAS were included in the study. AVAD in all patients was measured by transthoracic echocardiograph (AVAD-TTE) and in 74 patients of them was measured intra-operatively (AVAD-intra)...
April 1, 2012: Catheterization and Cardiovascular Interventions
https://read.qxmd.com/read/20018521/the-modified-ross-operation-using-a-dacron-prosthetic-vascular-jacket-does-prevent-pulmonary-autograft-dilatation-at-4-5-year-follow-up
#27
JOURNAL ARTICLE
Faleh Al Rashidi, Misha Bhat, Peter Höglund, Carl Meurling, Anders Roijer, Bansi Koul
OBJECTIVE: Following the Ross operation, pulmonary autografts tend to dilate over time. This study researches the fate of the pulmonary autograft - at 4.5 years following the modified Ross operation - with special reference to the impact of the modification on (a) pulmonary autograft dilatation, (b) the neo-aortic root geometry, (c) neo-aortic valve function and (d) the coronary artery reserve. METHODS: A total of 26 patients who underwent the Ross operation were included in this study; of these, 13 consecutive patients underwent a modified Ross operation in which the free-standing autograft root was supported externally by a Dacron vascular prosthetic jacket (DVPJ)...
April 2010: European Journal of Cardio-thoracic Surgery
https://read.qxmd.com/read/19411177/mid-term-echocardiographic-results-with-different-rings-following-restrictive-mitral-annuloplasty-for-ischaemic-cardiomiopathy
#28
JOURNAL ARTICLE
Francesco Onorati, Antonino Salvatore Rubino, Domenico Marturano, Eugenia Pasceri, Giuseppina Mascaro, Stefania Zinzi, Filiberto Serraino, Attilio Renzulli
BACKGROUND: Despite restrictive mitral annuloplasty (RMA) being considered effective for chronic ischaemic mitral regurgitation (CIMR), few data exist on mid-term echocardiographic results with different prosthetic rings. Therefore, comparative echocardiographic analysis has been performed. METHODS: Sixty-four consecutive coronary artery bypass graft surgery (CABG) + RMA (downsizing by two-ring sizes; median size: 26 mm) for CIMR with a follow-up of at least 6 months were prospectively followed-up with serial echocardiograms (preoperative, discharge, 6 months, follow-up ending)...
August 2009: European Journal of Cardio-thoracic Surgery
https://read.qxmd.com/read/18296411/doppler-echocardiographic-assessment-of-ttk-chitra-prosthetic-heart-valve-in-the-mitral-position
#29
JOURNAL ARTICLE
Narayanan Namboodiri, Othayoth Shajeem, Jaganmohan A Tharakan, R Sankarkumar, Thomas Titus, Ajitkumar Valaparambil, Sivasubramonian Sivasankaran, Kavassery Mahadevan Krishnamoorthy, Sivadasan Pillai Harikrishnan, Santosh Kumar Dora
AIMS: TTK Chitra heart valve prosthesis (CHVP), a tilting disc mechanical heart valve of low cost and proven efficacy, has been in use for the last 15 years. Although various studies substantiating its long-term safety and efficacy are available, no study had assessed its echocardiographic characteristics. The purpose of this study was to determine the normal Doppler parameters of CHVP in the mitral position and to assess whether derivation of mitral valve area (MVA) using the continuity equation (CE) and more commonly used pressure half-time (PHT) method is comparable in the functional assessment of this tilting disc mitral prosthesis...
September 2008: European Journal of Echocardiography
https://read.qxmd.com/read/18095909/diagnosis-and-treatment-of-left-sided-prosthetic-valve-thrombosis
#30
REVIEW
Maria Lengyel
Left-sided prosthetic valve thrombosis is a life-threatening complication of the mechanical valves. Prosthetic valve thrombosis has been divided into obstructive forms (OPVT) and nonobstructive forms (NOPVT). Clinical presentation of OPVT is heart failure and systemic embolism of OPVT and NOPVT, but it may be asymptomatic. Transesophageal echocardiography is the technique of choice for diagnosis and treatment guidance. There are three treatment options. Surgery carries a high hospital mortality risk in severely sick patients...
January 2008: Expert Review of Cardiovascular Therapy
https://read.qxmd.com/read/18065336/evaluation-of-hemodynamic-changes-in-patients-with-mitral-valve-replacement-using-dobutamine-stress-echocardiography
#31
JOURNAL ARTICLE
A Tulga Ulus, Ufuk Tütün, Baran Budak, Sakine Erbaş, Nurcan Arat, Seher Bozboğa, Kenan Köse, Mustafa Seren, Ali Ihsan Parlar, Ayşen Aksöyek, Salih Fehmi Katircioğlu
OBJECTIVE: The aim of this study was to investigate the response of heart to stress according to the size of the prosthetic valve in patients who had undergone mitral valve replacement by using dobutamine stress echocardiography (DSE) and to evaluate the relationship between the size of the prosthetic valve and cardiac recovery-remodeling process. METHODS: Thirty-nine patients, who had undergone mitral valve replacement were compared in terms of left ventricular diameters, systolic functions and cardiac mass indexes in order to investigate the effect of the mechanical valve size on postoperative cardiac remodeling in this longitudinal study...
December 2007: Anatolian Journal of Cardiology: AKD
https://read.qxmd.com/read/18023677/comparison-of-eight-prosthetic-aortic-valves-in-a-cadaver-model
#32
COMPARATIVE STUDY
Benjamin A Youdelman, Hitoshi Hirose, Harsh Jain, J Yasha Kresh, John W C Entwistle, Andrew S Wechsler
OBJECTIVES: Proper valve selection is critical to ensure appropriate valve replacement for patients, because implantation of a small valve might place the patient at risk for persistent gradients. Labeled valve size is not the same as millimeter measure of prosthetic valve diameters or the annulus into which it will fit. Studies that use the labeled valve size in lieu of actual measured diameter in millimeters to compare different valves might be misleading. Using human cadaver hearts, we sized the aortic annulus with 8 commonly used prosthetic aortic valve sizers and compared the valves using geometric orifice area...
December 2007: Journal of Thoracic and Cardiovascular Surgery
https://read.qxmd.com/read/17668572/-konno-aortoventriculoplasty-indications-and-results-13-cases
#33
JOURNAL ARTICLE
Mourad Djebbi, Ali Walid Ben, Mehdi Chihaoui, Mourad Hakim, Faker Guedira, Raouf Denguir, Taoufik Kalfat, Adel Khayati, Abdelfatteh Abid
BACKGROUND: Konno procedure is used to enlarge the aortic root and increase the size of the aortic valve implanted. AIM: The aim of this study is to present the indications of the Konno procedure in congenital and acquired aortic lesions, in young patients with normal or hypoplastic aortic annulus or adults with small aortic annulus. METHODS: We reported our experience of this technique with a retrospective study of 13 patients operated on between 1998 and 2004...
March 2007: La Tunisie Médicale
https://read.qxmd.com/read/17405561/-the-best-of-valvular-heart-disease-in-2006
#34
REVIEW
G de Gevigney
In the field of valvular diseases, the year 2006 has been above all marked by the publication of new joint AHA/ACC guidelines. Besides, other publications included severe aortic stenosis, drug therapy in chronic aortic regurgitation, the indications for surgery in asymptomatic mitral regurgitation, as well as valve surgery in the elderly and mismatch severity after aortic valve replacement. In a series of 66 cases of aortic stenosis with poor LV function undergoing stress echocardiography, it has been shown that whether the absence of contractile reserve identifies a high-risk subgroup for aortic valve replacement (33% vs...
January 2007: Archives des Maladies du Coeur et des Vaisseaux
https://read.qxmd.com/read/17342036/dobutamine-stress-echocardiography-and-left-ventricular-mass-changes-of-mechanical-aortic-valve-replacement-in-four-years-follow-up
#35
RANDOMIZED CONTROLLED TRIAL
A Tulga Ulus, S Erbas, B Budak, U Tütün, A Aksöyek, F Ciçekçioglu, M Seren, N Arat, S Fehmi Katircioglu
AIM: The aim of this study was to investigate the differences in cardiac response to stress according to the size of the prosthetic valve in patients who underwent aortic valve replacement (AVR) and to evaluate the relationship between the size of the prosthetic valve and cardiac recovery-remodeling after the operation. METHODS: Thirty patients who had undergone AVR (12 patients) or double valve replacement (18 patients) underwent dobutamine-stress echocardiography 4...
April 2007: Minerva Cardioangiologica
https://read.qxmd.com/read/17152782/the-influence-of-prosthesis-size-and-design-on-exercise-dynamics-after-aortic-valve-replacement
#36
JOURNAL ARTICLE
Niaz F Ali, Vinod S Mahadevan, Andrew Muir, Christine Maguire, David Young, Gianfranco Campalani, Norman P S Campbell, Mark H D Danton
BACKGROUND AND AIM OF THE STUDY: Residual gradient following aortic valve replacement (AVR) may adversely affect clinical outcome. The size and design of the valve may influence these characteristics. The study aim was to determine the influence of prosthesis physical size and leaflet design on hemodynamic performance after mechanical AVR. METHODS: After AVR, two patient groups with a range of valve sizes were studied. Group 1 patients (n=19) each received a monoleaflet valve; group 2 patients (n=18) each received a bileaflet valve...
November 2006: Journal of Heart Valve Disease
https://read.qxmd.com/read/16519129/midterm-results-of-mitral-valve-repair-with-the-carpentier-edwards-rigid-ring
#37
JOURNAL ARTICLE
Yoshimasa Sakamoto, Kazuhiro Hashimoto, Hiroshi Okuyama, Shinichi Ishii, Shingo Taguchi, Hiroshi Kagawa, Michio Yoshitake
OBJECTIVE: Prosthetic annuloplasty rings play an important role in mitral valve repair. This clinical study was undertaken to evaluate the midterm results obtained with the Carpentier-Edwards rigid ring. METHODS: Between October 1991 and March 2005, 112 patients (mean age 53.0 years) underwent mitral valve repair with a Carpentier-Edwards rigid ring at our institution. Degenerative disease was the most frequent cause and a small number had other conditions such as endocarditis and rheumatic disease...
February 2006: Japanese Journal of Thoracic and Cardiovascular Surgery
https://read.qxmd.com/read/15473486/doppler-assessment-of-mechanical-aortic-valve-prostheses-effect-of-valve-design-and-size-of-the-aorta
#38
COMPARATIVE STUDY
Julia Mascherbauer, Heinrich Schima, Gerald Maurer, Helmut Baumgartner
BACKGROUND AND AIM OF THE STUDY: Discrepancies between Doppler and catheter gradients have been reported for bileaflet aortic valve prostheses. Whether modifications in geometric design of newly developed bileaflet valves lead to a different Doppler-catheter gradient relationship has not been evaluated. Variable results have been reported for tilting-disc prostheses. In addition, the effect of aortic size on the Doppler-catheter gradient relationship remains unclear. METHODS: Various sizes of On-X and Edwards Mira (identical with Sorin Bicarbon) bileaflet valves and Sorin Allcarbon tilting-disc aortic valves (19-25 mm) were studied in a pulsatile flow model...
September 2004: Journal of Heart Valve Disease
https://read.qxmd.com/read/15473468/a-versatile-technique-for-aortic-root-replacement-without-pre-manufactured-composite-graft-a-12-year-experience
#39
JOURNAL ARTICLE
James C Halstead, Eric Lim, Ayyaz Ali, Steven Tsui, Stephen Large, John Wallwork, John Dunning
BACKGROUND AND AIM OF THE STUDY: Replacement of the aortic root is the treatment of choice for aneurysmal dilatation. Many modifications of the Bentall technique have been described, as have valve-sparing procedures. The study aim was to determine the outcome of a versatile modification of composite replacement that has been adopted over the past 12 years. Separate graft and prosthetic valve components were used to allow freedom of valve choice and the use of an appropriately sized graft for the distal aortic anastomosis...
September 2004: Journal of Heart Valve Disease
https://read.qxmd.com/read/15364842/prospectively-randomized-evaluation-of-stented-xenograft-hemodynamic-function-in-the-aortic-position
#40
RANDOMIZED CONTROLLED TRIAL
Thomas Walther, Sven Lehmann, Volkmar Falk, Sebastian Metz, Nicolas Doll, Ardawan Rastan, Marika Viehweg, Markus Richter, Jan Gummert, Friedrich W Mohr
BACKGROUND: Standard stented aortic xenograft valves have not yet been compared regarding their hemodynamic function using a stratified intraoperative randomization protocol. METHODS AND RESULTS: 100 patients were prospectively included after intraoperative metric sizing of the decalcified aortic annulus. They received Mosaic (M) or Perimount (P) aortic valve replacement. Patient age was 73+/-5 years, 51 were female, and New York Heart Association (NYHA) functional class was 2...
September 14, 2004: Circulation
keyword
keyword
15555
2
3
Fetch more papers »
Fetching more papers... Fetching...
Remove bar
Read by QxMD icon Read
×

Save your favorite articles in one place with a free QxMD account.

×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"

We want to hear from doctors like you!

Take a second to answer a survey question.