keyword
https://read.qxmd.com/read/38679136/reliability-of-a-face-scanner-in-measuring-the-vertical-dimension-of-occlusion
#1
JOURNAL ARTICLE
Murali Srinivasan, Florentin Berisha, Innocenzo Bronzino, Porawit Kamnoedboon, Claudio Rodrigues Leles
OBJECTIVE: This study evaluated the reliability of a face scanner in measuring the vertical dimension of occlusion (VDO). METHODS: Fully dentate volunteers (n=20; mean-age=30.0±10.7 years) were recruited. Clinical facial measurements were obtained using a digital caliper and a face scanner (Class 1 LASER, Obiscanner, Fifthingenium, Italy). The scans were imported into a mesh-processing software, and the distances were measured digitally. Measurements were obtained for each participant with the jaws positioned in maximal intercuspation (MI) and with increased vertical distances of 2, 4, and 6 mm...
April 26, 2024: Journal of Dentistry
https://read.qxmd.com/read/38678747/influence-of-additives-and-binder-on-the-physical-properties-of-dental-silicate-glass-ceramic-feedstock-for-additive-manufacturing
#2
JOURNAL ARTICLE
Moritz Hoffmann, Bogna Stawarczyk, Jens Günster, Andrea Zocca
OBJECTIVES: The aim of the study was to investigate the impact of organic additives (binder, plasticizer, and the cross-linking ink) in the formulation of water-based feedstocks on the properties of a dental feldspathic glass-ceramic material developed for the slurry-based additive manufacturing technology "LSD-print." MATERIAL AND METHODS: Three water-based feldspathic feedstocks were produced to study the effects of polyvinyl alcohol (AC1) and poly (sodium 4-styrenesulfonate) (AC2) as binder systems...
April 25, 2024: Journal of the Mechanical Behavior of Biomedical Materials
https://read.qxmd.com/read/38678374/effects-of-different-antiviral-mouthwashes-on-the-surface-roughness-hardness-and-color-stability-of-composite-cad-cam-materials
#3
JOURNAL ARTICLE
Ahmet Hazar, Ecehan Hazar
OBJECTIVE: To evaluate the effect of COVID-19 preventive mouthwashes on the surface hardness, surface roughness (Ra), and color change (ΔE) of three different polymer-based composite CAD/CAM materials (Vita Enamic (ENA), Grandio Block (GB), Lava Ultimate (LU)). METHODS: A total of 100 rectangular-shaped specimens with dimensions of 2 mm × 7 mm × 12 mm were obtained by sectioning three different CAD/CAM blocks and randomly divided into five subgroups according to the 30 days of mouthwash immersion protocol as follows: Control: artificial saliva, PVP-I: 1% povidone-iodine, HP: 1...
2024: Journal of Applied Biomaterials & Functional Materials
https://read.qxmd.com/read/38676830/development-of-a-universal-cutting-guide-for-raising-deep-circumflex-iliac-artery-flaps
#4
JOURNAL ARTICLE
Florian Peters, Stefan Raith, Anna Bock, Kristian Kniha, Stephan Christian Möhlhenrich, Marius Heitzer, Frank Hölzle, Ali Modabber
PURPOSE: The deep circumflex iliac crest flap (DCIA) is used for the reconstruction of the jaw. For fitting of the transplant by computer-aided planning (CAD), a computerized tomography (CT) of the jaw and the pelvis is necessary. Ready-made cutting guides save a pelvic CT and healthcare resources while maintaining the advantages of the CAD planning. METHODS: A total of 2000 CTs of the pelvis were divided into groups of 500 by sex and age (≤ 45 and > 45 years)...
April 27, 2024: International Journal of Computer Assisted Radiology and Surgery
https://read.qxmd.com/read/38675038/suitability-and-trueness-of-the-removable-partial-denture-framework-fabricating-by-polyether-ether-ketone-with-cad-cam-technology
#5
JOURNAL ARTICLE
Kening Zhao, Su Wu, Chao Qian, Jian Sun
The object of the study was to evaluate the suitability and trueness of the removable partial denture (RPD) framework fabricated by polyether ether ketone (PEEK) with the CAD-CAM technology in vitro. Four different types of dentition defects were selected. In each type, five PEEK RPD frameworks were fabricated by the CAD-CAM technology, while five Co-Cr RPD frameworks were made by traditional casting. The suitability of the framework was evaluated by silicone rubber film slice measurement and the three-dimensional image overlay method...
April 17, 2024: Polymers
https://read.qxmd.com/read/38673631/comparison-between-conventional-and-digital-impressions-for-determining-axes-and-distances-of-three-implants-in-straight-and-curved-lines-an-in-vitro-study
#6
JOURNAL ARTICLE
Gil Ben-Izhack, Ophir Rosner, Eran Zenziper, Joseph Nissan, Reema Hosary, Diva Lugassy, Asaf Shely
Background : In this study, we aimed to compare the effects of conventional and digital impressions on several parameters (inter-implant distance, intra-implant distance, inter-implant axis, and intra-implant axis) of three implants in curved lines and straight lines by using a laboratory scanner (LBS) versus an intra-oral scanner (IOS). Methods : Two 3D models were fabricated using a printer, each model with three internal hex implants analogues at the positions of 15#,16#,17# (straight line) and 12#,13#,14# (curved line)...
April 18, 2024: Journal of Clinical Medicine
https://read.qxmd.com/read/38670333/comparison-of-clinical-efficacy-of-cad-cam-endocrowns-made-of-feldspathic-zirconia-lithium-silicate-and-lithium-disilicate-a-two-year-mixed-cohort-study
#7
JOURNAL ARTICLE
Samar Jalali, Nafise Asgari, Parsa Pirooz, Shima Younespour, Faezeh Atri
OBJECTIVE: Endocrowns can be fabricated from various materials as a treatment option for endodontically treated teeth. This mixed cohort study aimed to demonstrate the clinical efficacy of endocrowns made of feldspathic, zirconia lithium silicate, and lithium disilicate ceramics using a chairside CAD/CAM system. METHODS: The present study compared the clinical outcomes of 141 endocrown restorations in posterior teeth of 85 patients in a two-year follow-up. The efficacy of restorations was evaluated in three aspects: esthetics, biological response, and function, with the aid of the FDI guideline, and presented as descriptive analyses...
April 24, 2024: Journal of Dentistry
https://read.qxmd.com/read/38670331/fracture-characteristics-and-translucency-of-multilayer-monolithic-zirconia-crowns-of-various-thicknesses
#8
JOURNAL ARTICLE
Chien-Ming Kang, Wen-Chieh Hsu, May-Show Chen, Hsuan-Yu Wu, Yuichi Mine, Tzu-Yu Peng
OBJECTIVES: Multilayer monolithic zirconia (M-Zr) crowns can be engineered to achieve gradational translucency and color intensity. However, this modification may compromise the mechanical strength, raising concerns regarding the ability of M-Zr crowns to withstand occlusal stresses. The effects of M-Zr crown thickness on translucency and ability to endure occlusal forces were investigated at different tooth positions (incisors, premolars, and molars). The objective was to determine the minimal thickness of M-Zr crowns used in tooth preparation to meet aesthetic and functional demands...
April 24, 2024: Journal of Dentistry
https://read.qxmd.com/read/38669369/manufacturing-of-peek-orthodontic-baseplate-and-3d-printed-alloy-components-from-an-intraoral-scan
#9
JOURNAL ARTICLE
Noor A Al Mortadi, Lina Khasawneh, Karem H Alzoubi
This paper demonstrates a digital manufacturing technique of a removable orthodontic appliance from an intraoral scan. An intraoral scan was made for the maxillary and mandibular arches. 3Shape Orthodontics Appliance Designer produced the virtual Hawley retainer, consisting of alloy components (Adam Clasps and Fitted Labial bow) and a base plate. The base plate design was modified to adapt to inserting the alloy components, which were combined using cold-cured acrylic. The finished Hawley retainer was assessed intraorally...
April 26, 2024: Medicine (Baltimore)
https://read.qxmd.com/read/38668159/impact-of-nanoparticle-addition-on-the-surface-and-color-properties-of-three-dimensional-3d-printed-polymer-based-provisional-restorations
#10
JOURNAL ARTICLE
Maram A AlGhamdi, Fatimah M Alatiyyah, Rawan F Almedarham, Zainab H Al Dawood, Farah Y Alshaikhnasser, Shaymaa Y Alboryh, Soban Q Khan, Reem Abualsaud, Mohammed M Gad
This study aimed to evaluate and compare the impact of additives such as ZrO2 and SiO2 nanoparticles (ZrO2 NP or SiO2 NP) on the hardness, surface roughness, and color stability of 3D printed provisional restorations. Two hundred samples in total were printed using 3D printed resins (ASIGA, and NextDent). Each resin was modified with ZrO2 NPs or SiO2 NPs in two different concentrations (0.5 wt% and 1 wt%), while one group was kept unmodified (n = 10). Disc-shaped (15 × 2.5 mm) samples were designed and printed in accordance with the manufacturer's recommendation...
April 11, 2024: Nanomaterials
https://read.qxmd.com/read/38668006/impact-of-scanbody-geometry-and-cad-software-on-determining-3d-implant-position
#11
JOURNAL ARTICLE
Judith Kropfeld, Lara Berger, Werner Adler, Katja Leonie Schulz, Constantin Motel, Manfred Wichmann, Ragai Edward Matta
The implementation of CAD software in the digital production of implant prosthetics stands as a pivotal aspect of clinical dentistry, necessitating high precision in the alignment of implant scanbodies. This study investigates the influence of scanbody geometry and the method of superimposing in CAD software when determining 3D implant position. A standardized titanium model with three bone-level implants was digitized to create reference STL files, and 10 intraoral scans were performed on Medentika and NT-Trading scanbodies...
April 3, 2024: Dentistry Journal
https://read.qxmd.com/read/38666691/clinical-outcomes-of-milled-3d-printed-and-conventional-complete-dentures-in-edentulous-patients-a-systematic-review-and-meta-analysis
#12
REVIEW
Amirali Zandinejad, Franciele Floriani, Wei-Shao Lin, Aron Naimi-Akbar
PURPOSE: This systematic review aims to compare clinical outcomes of digital dentures with conventional dentures. MATERIALS AND METHODS: This study followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines and was registered in Prospero. The formulated population, intervention, comparison, outcome (PICO) question was "What is the clinical outcome of digital versus conventional complete dentures (CDs) in edentulous patients?"...
April 26, 2024: Journal of Prosthodontics: Official Journal of the American College of Prosthodontists
https://read.qxmd.com/read/38665052/influence-of-ceramic-crown-design-translucent-monolithic-zirconia-vs-bilayered-of-implant-supported-single-crowns-after-mechanical-cycling
#13
JOURNAL ARTICLE
Joao Pedro Justino de Oliveira Limirio, Jéssica Marcela de Luna Gomes, Joel Ferreira Santiago-Junior, Bruna Egumi Nagay, Aldiéris Alves Pesqueira, Wirley Gonçalves Assunção, Maria Cristina Rosifini Alves-Rezende, Eduardo Piza Pellizzer
OBJECTIVES: This study aimed to assess the influence of translucent monolithic versus bilayered crowns and whether the use of a CoCr base abutments affects the fatigue and fracture resistance of screwed implant-supported single crowns with external connections under mechanical cycling. MATERIALS AND METHODS: Fifty specimens were divided into groups: (1) metal-ceramic (MC) crown, (2) veneered zirconia crown (Zr), (3) veneered zirconia crown with a CoCr base abutment (ZrB), (4) monolithic translucent zirconia crown (MZr), and (5) monolithic translucent zirconia crown with a CoCr base abutment (MZrB)...
April 25, 2024: Journal of Esthetic and Restorative Dentistry
https://read.qxmd.com/read/38657286/how-do-different-intraoral-scanners-and-milling-machines-affect-the-fit-and-fatigue-behavior-of-lithium-disilicate-and-resin-composite-endocrowns
#14
JOURNAL ARTICLE
Rafaela Oliveira Pilecco, Lucas Saldanha da Rosa, Andrea Baldi, Renan Vaz Machry, João Paulo Mendes Tribst, Luiz Felipe Valandro, Cornelis Johannes Kleverlaan, Nicola Scotti, Gabriel Kalil Rocha Pereira
The aim of this in vitro study was to evaluate the effect of the combinations of two different intraoral scanners (IOS), two milling machines, and two restorative materials on the marginal/internal fit and fatigue behavior of endocrowns produced by CAD-CAM. Eight groups (n= 10) were considered through the combination of TRIOS 3 (TR) or Primescan (PS) IOS; 4-axes (CR; CEREC MC XL) or 5-axes (PM; PrograMill PM7) milling machines; and lithium disilicate (LD; IPS e.max CAD) or resin composite (RC; Tetric CAD) restorative materials...
April 18, 2024: Journal of the Mechanical Behavior of Biomedical Materials
https://read.qxmd.com/read/38657218/guided-and-prosthetically-driven-bone-augmentation-using-the-shell-technique-and-allogeneic-cortical-plate-a-prospective-case-series
#15
JOURNAL ARTICLE
Romain Doliveux, Simon Doliveux
PURPOSE: To describe the use of digital technology to surgically guide the shell technique using allogenic cortical plates for a fully guided bone augmentation procedure. MATERIALS AND METHODS: A total of 10 patients who required bone augmentation for implant placement were included in this study. Allogenic cortical plates were planned using CAD/CAM to have identical thickness to the original cortical plates, then were digitally positioned and shaped to outline the bone defect according to the existing anatomical details...
April 24, 2024: International Journal of Oral & Maxillofacial Implants
https://read.qxmd.com/read/38644230/shear-bond-strength-of-ultraviolet-polymerized-resin-to-3d-printed-denture-materials-effects-of-post-polymerization-surface-treatments-and-thermocycling
#16
JOURNAL ARTICLE
Ami Tanaka, Tomohiro Kawaguchi, Ayaka Ito, Kota Isshi, Ippei Hamanaka, Takashi Tsuzuki
PURPOSE: The purpose of this study is to compare the shear bond strength of ultraviolet (UV)-polymerized resin to 3D-printed denture materials, both with and without post-polymerization. Moreover, the effects of surface treatment and thermocycling on shear bond strength after post-polymerization were investigated. METHODS: Cylindrical 3D-printed denture bases and teeth specimens were prepared. The specimens are subjected to two tests. For Test 1, the specimens were bonded without any surface treatment or thermal stress for comparison with and without post-polymerization...
April 19, 2024: Journal of Prosthodontic Research
https://read.qxmd.com/read/38644215/influence-of-resin-coating-techniques-on-the-marginal-adaptation-and-the-bond-strengths-of-cad-cam-fabricated-hybrid-ceramic-inlays
#17
JOURNAL ARTICLE
Yuna Kanamori, Rena Takahashi, Toru Nikaido, Hiroshi Nitta, Yasushi Shimada, Junji Tagami, Karl-Heinz Kunzelmann
This study aimed to evaluate the effects of different resin-coating technique strategies and dual-cure resin luting materials on proximal marginal adaptation and the microtensile bond strengths (μTBSs) of CAD/CAM hybrid ceramic inlays. Extracted human molars were classified into four groups, depending on the coating technique: No coating (None), single coating (1-coating), double coating (2-coating), and flowable resin-coating (Combination). The inlays were bonded with one of the three materials: Panavia V5 (V5), Rely X Ultimate (RXU), and Calibra Ceram (CC)...
April 19, 2024: Dental Materials Journal
https://read.qxmd.com/read/38638109/impact-of-various-aging-treatments-on-the-microhardness-and-surface-roughness-of-cad-cam-monolithic-restorative-materials
#18
JOURNAL ARTICLE
Gonca Deste Gökay, Perihan Oyar, Rukiye Durkan
PURPOSE: Dental ceramics deteriorate as a result of thermal aging and exposure to acidic solutions, which change their microhardness and surface roughness. This study assessed the resistance of several computer-aided design and computer-aided manufacturing (CAD-CAM) restorative dental materials in terms of surface roughness and microhardness following exposure to acidic solutions and thermal aging. MATERIALS AND METHODS: Five different monolithic CAD-CAM restorative materials, two leucite-reinforced glass ceramics (G-Ceram and CEREC Blocs), a zirconia-infiltrated lithium silicate (Celtra Duo), a resin nanoceramic (Grandio), and monolithic zirconia (inCoris TZI), were used to create 2-mm-thick rectangular specimens (n = 100)...
April 19, 2024: Journal of Prosthodontics: Official Journal of the American College of Prosthodontists
https://read.qxmd.com/read/38634968/effect-of-cement-type-on-vertical-marginal-discrepancy-and-residual-excess-cement-in-screwmentable-and-cementable-implant-supported-monolithic-zirconia-crowns
#19
JOURNAL ARTICLE
Pınar Yıldız, Göknil Alkan Demetoğlu, Esra Talay Çevlik
The purpose of this study was to investigate the vertical marginal discrepancy (VMD) and residual excess cement (REC) of cementable and screwmentable monolithic zirconia crowns cemented with different types of cement. Abutments were attached to 40 implant analogues. Crowns were created using computer-aided design/computer-aided manufacturing technology from monolithic zirconia blocks, either with or without a screw access hole (SAC). Crowns created both ways were split into two groups and cemented with resin and zinc polycarboxylate cement under a 5-kg weight...
April 18, 2024: Odontology
https://read.qxmd.com/read/38627819/3d-printing-vs-traditional-workflow-for-the-fabrication-of-mandibular-implant-overdentures-study-protocol-for-a-mixed-methods-cross-over-rct
#20
JOURNAL ARTICLE
Dana Jafarpour, Nesma El-Amier, Jocelyne Feine, Christophe Bedos, Samer Abi-Nader, Shahrokh Esfandiari, Tibor Shuster, Elizabeth Zimmermann, Raphael de Souza
BACKGROUND: Complete tooth loss is a significant global oral health issue, particularly impacting older individuals with lower socioeconomic status. Computer-assisted technologies enhance oral healthcare access by the elderly. Despite promising in vitro reports on digital denture materials, evidence from randomized clinical trials (RCTs) is lacking to verify their performance. This cross-over RCT will investigate whether 3D-printed implant-retained mandibular overdentures (IMO) are more satisfactory for edentulous seniors than those made through traditional methods...
April 16, 2024: Trials
keyword
keyword
11178
1
2
Fetch more papers »
Fetching more papers... Fetching...
Remove bar
Read by QxMD icon Read
×

Save your favorite articles in one place with a free QxMD account.

×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"

We want to hear from doctors like you!

Take a second to answer a survey question.