Reducing unnecessary preoperative blood orders and costs by implementing an updated institution-specific maximum surgical blood order schedule and a remote electronic blood release system.

Anesthesiology 2014 September
BACKGROUND: Using blood utilization data acquired from the anesthesia information management system, an updated institution-specific maximum surgical blood order schedule was introduced. The authors evaluated whether the maximum surgical blood order schedule, along with a remote electronic blood release system, reduced unnecessary preoperative blood orders and costs.

METHODS: At a large academic medical center, data for preoperative blood orders were analyzed for 63,916 surgical patients over a 34-month period. The new maximum surgical blood order schedule and the electronic blood release system (Hemosafe; Haemonetics Corp., Braintree, MA) were introduced mid-way through this time period. The authors assessed whether these interventions led to reductions in unnecessary preoperative orders and associated costs.

RESULTS: Among patients having surgical procedures deemed not to require a type and screen or crossmatch (n = 33,216), the percent of procedures with preoperative blood orders decreased by 38% (from 40.4% [7,167 of 17,740 patients] to 25.0% [3,869 of 15,476 patients], P < 0.001). Among all hospitalized inpatients, the crossmatch-to-transfusion ratio decreased by 27% (from 2.11 to 1.54; P < 0.001) over the same time period. The proportion of patients who required emergency release uncrossmatched blood increased from 2.2 to 3.1 per 1,000 patients (P = 0.03); however, most of these patients were having emergency surgery. Based on the realized reductions in blood orders, annual costs were reduced by $137,223 ($6.08 per patient) for surgical patients, and by $298,966 ($6.20/patient) for all hospitalized patients.

CONCLUSION: Implementing institution-specific, updated maximum surgical blood order schedule-directed preoperative blood ordering guidelines along with an electronic blood release system results in a substantial reduction in unnecessary orders and costs, with a clinically insignificant increase in requirement for emergency release blood transfusions.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app